17
Problem Cause Remedy
LED
is lit.
The coffee
grounds con-
tainer is full.
Empty coffee grounds container,
►“Cleaning the appliance” from
page 13.
LED
ashes.
The coffee
grounds con-
tainer has not
been properly
inserted.
Insert coffee grounds container
properly, ►“Cleaning the appliance”
on page 13.
LED
is lit.
The brewing
unit has not
been properly
inserted.
Insert brewing unit properly,
►“Cleaning the appliance” on
page 13.
LED
ashes.
Maintenance
lid has not
been properly
attached.
Attach maintenance lid properly,
►“Cleaning the appliance” on
page 13.
Appliance can
not be switched
on.
The appliance
is not con-
nected to the
power supply.
Connect power cord to power supply
of appliance.
Plug the power plug into a shock-
proof socket.
Problem Cause Remedy
The buttons re-
spond delayed
or not at all.
Appliance is
disturbed by
electromag-
netic elds.
Switch the appliance off and discon-
nect the plug. Wait a few minutes.
Plug power plug back into socket and
switch appliance on again.
Buttons are
soiled.
Clean the surface of the appliance
with the provided cloth or another
soft, lint-free cloth.
Buttons
pressed too
far up.
Use a pressure point slightly under-
neath the lighted symbols.
Coffee is too
cold.
Scale accu-
mulation in
appliance.
Descale the appliance, ►“Descaling
the appliance” on page 15.
Coffee does
not ow from
outlet.
Grind is set too
high, clogging
the brewing
unit.
Set a coarser grind, ►“Adjusting the
grind” on page 11.
Prior to this,
appliance was
emptied or was
not ushed
before rst use.
Draw hot water from outlet by using
the function ►“Drawing hot water”
on page 11.

Related product manuals