INTERBUS UFI11A Fieldbus Interface
Edition
06/2002
Manual
1052 5114 / EN
Question and Answer IconNeed help?

Do you have a question about the SEW-Eurodrive INTERBUS UFI11A and is the answer not in the manual?

SEW-Eurodrive INTERBUS UFI11A Specifications

General IconGeneral
BrandSEW-Eurodrive
ModelINTERBUS UFI11A
CategoryRecording Equipment
LanguageEnglish

Summary

Overview of the System

Copying data

Method for copying UFI11A settings using the UBP11A parameter module.

Unit Structure

Front view

Arrangement of LEDs, connectors, and DIP switches on the UFI11A unit.

Installation and Operation with Autosetup

Installation notes

Notes on mounting and pin assignment for the fieldbus interface unit.

Setting the inverter parameters

Procedures for configuring inverter parameters for operation with the UFI11A.

Autosetup

Enabling and using the Autosetup function for automatic configuration.

Configuration of the fieldbus master

Steps to configure the INTERBUS fieldbus master software and settings.

Starting the inverters

Steps for initiating and operating connected inverters via INTERBUS.

Installation and Operation with a PC

PC connection

Details on connecting the UFI11A to a PC via the UWS21A option.

Startup software

Instructions for installing and using MOVITOOLS for UFI11A configuration.

INTERBUS Interface

Startup of the INTERBUS master

Setting up the INTERBUS bus structure using the CMD Tool.

Configuration of the INTERBUS interface

Configuring INTERBUS data length and PCP length using DIP switches.

PCP interface

Overview of PCP services for parameter setting and communication.

Return codes for parameter setting

Explanation of return codes for parameter setting errors.

Autosetup

Procedure for starting up the UFI11A without a PC using the Autosetup function.

Error Response

Fieldbus timeout

Response to a fieldbus timeout error and its self-resetting behavior.

SBus timeout

Handling of SBus timeout errors and their impact on inverter status.

Unit errors

Detection and response to hardware defects in UFI11A fieldbus interfaces.

Diagnostic LEDs

States of the LEDs UL, RC, BA, TR and RD

Meaning and troubleshooting for diagnostic LEDs UL, RC, BA, TR, and RD.

DIP Switches

Application examples

Control via process data

Example of controlling drive inverters via process data exchange.

Parameter setting via the PCP interface

Reading/writing parameters using INTERBUS PCP services.

Writing of UFI11A or drive parameters via object 8288

Mechanism for writing parameters using object 8288.

Parameter List

List of Errors

Technical Data

Dimensions

Index

Related product manuals