SI 480E DIN SIZE WEIGHING CONTROLER
5-2-5. Input Test Weight value and Calculate SPAN value.
If “SPAN” is displayed, input “Test Weight” capacity and press key.
If “UP” is displayed, please load “Test Weight” on the scale part and press key.
Calculate Span value during 10 ~20 secs,
automatically.
※ Over than 1/10,000 resolution setting,
To guarantee the preciseness, Span calculation will be operated twice.
After calculation, span value will be displayed
on the display. Then press key.
※This span value is not a weight value.
When “ END” is displayed and calibration is
completed.