SI 480E DIN SIZE WEIGHING CONTROLER
■ F-Function List
General Function Setting (“●” Factory default set value)
Weighing Data Save Method selection
Non-Save Mode (Weight Data & weighing counter)
Save Mode ( Weight Data & weighing counter)
Weight –Back up selection
Motion Band Range setting
This is set “Steady” acceptable range of weighing part.
If there is vibration on weighing part, you can set this function and reduce
the vibration effect on weighing process.
1 : Weak vibration ~~ 99 : Strong Vibration
Zero Tracking Compensation Range setting
Due to external causes (Temperature, wind, and dust), there will be small
weight difference, the Indicator will ignore the weight difference and
display as Zero.
Within the “Auto Zero” range, weighing part is steady, indicator will display
current weight as “Zero”
If the weighing part is not “Steady”, indicator will display current weight.
(Auto Zero Range : ± Set value + weight unit)
00 (Weak vibration ) ~ 40 (Strong Vibration)
Zero key Operation mode selection
Activate only under “Steady” condition
Zero key Operation Range selection : (-) value is same to (+)
Activated within 2% of Max. Capacity
Activated within 5% of Max. Capacity
Activated within 10% of Max. Capacity
Activated within 20% of Max. Capacity