SI 480E DIN SIZE WEIGHING CONTROLER
F-Function List
General Function Setting (“●” Factory default set value)
Weighing Data Save Method selection
F01
0
Non-Save Mode (Weight Data & weighing counter)
1
Save Mode ( Weight Data & weighing counter)
Weight Back up selection
F02
0
Normal Mode
1
Weight Back up Mode
Motion Band Range setting
F03
05
01
99
This is set Steady acceptable range of weighing part.
If there is vibration on weighing part, you can set this function and reduce
the vibration effect on weighing process.
1 : Weak vibration ~~ 99 : Strong Vibration
Zero Tracking Compensation Range setting
F04
05
00
99
Due to external causes (Temperature, wind, and dust), there will be small
weight difference, the Indicator will ignore the weight difference and
display as Zero.
Auto Zero Range setting
F05
00
00
99
Within the “Auto Zero” range, weighing part is steady, indicator will display
current weight as “Zero
If the weighing part is not “Steady”, indicator will display current weight.
(Auto Zero Range : ± Set value + weight unit)
Digital Filter setting
F06
04
00~40
00 (Weak vibration ) ~ 40 (Strong Vibration)
Zero key Operation mode selection
F07
0
Activate only under “Steady” condition
1
Always activate
Zero key Operation Range selection : (-) value is same to (+)
F08
0
Activated within 2% of Max. Capacity
1
Activated within 5% of Max. Capacity
2
Activated within 10% of Max. Capacity
3
Activated within 20% of Max. Capacity