EasyManua.ls Logo

Sewha SI 480E - Read Command Data Formats; Finished Weight Data Format; Current Time and Date Data Format; Tare Data Format

Sewha SI 480E
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
SI 480E DIN SIZE WEIGHING CONTROLER
4.Finished Weight data
ASCII : STX ID(2Byte) RFIN ETX
HEX: 02 30 31 52 46 49 4E 03
SI 480E response
STX ID RFIN P decimal point(1byte) +/- Finished weight(7byte)
ETX
Ex) Finished weight : 2.000kg decimal point
5. Current time Data
ASCII : STX ID(2Byte) RTIM ETX
HEX: 02 30 31 52 54 49 4D 03
SI 480E response
STX ID RTIM Current Time(6byte) ETX
Ex) Time : 12:00:00
6. Current date Data
ASCII : STX ID(2Byte) RDAT ETX
HEX : 02 30 31 52 44 41 54 03
SI 480E response
STX ID RDAT Current Date(6byte) ETX
Ex) Date : Aug 12
th
,2009
7. Tare data
ASCII : STX ID(2Byte) RTAR ETX
HEX : 02 30 31 52 54 41 52 03
SI 480E response
STX ID RTAR P decimal point(1byte) +/-(1byte) TARE value(7byte) ETX
Ex) TARE : 2.000kg decimal point
Recommended Interval of READ COMMAND is min.60ms, 70ms is
recommended, under 9600bps setting.
Min.60ms is required between each Read Command(under RCWD)
Min. interval is changed when datas length & speed are changed.
Min Interval : 20ms under 2400bps(RCWD)
Min Interval : 40ms under 115200bps (RCWD)

Related product manuals