SI 510 WEIGHING INDICATOR
In case of multiple pieces of load cells are installed, please make sum of each load
cell's capacity and make setting with max capacity.
EX) There are 4pcs of load cells and each load cell's max capacity is 1,000kg.
Then total max capacity will be 4,000kg (1,000 X 4) and you have to input 4,000.
STEP 3 – Setting "Capacity of Load Cell"
1) "CAPA" become displayed.
2) Check the Max Capacity of Load Cell and
Input the Max Capacity to Load cell. (Refer to
the load cell label or Test Report.) And Press
"ENTER" key.
STEP 4 – Setting "Digit / Division" value
1) After "DIVI" is displayed, locate the
decimal point with "F1"key.
2) Set the division with "F2" key.
Press enter key to save.