CESSNA 182Q QRH
Page 25 of 33
C182Q QRH JAN 2022
*If fire is not extinguished, increase glide speed to find an airspeed
which will provide an incombustible mixture
7. Forced Landing ……………………………………………………….………… EXECUTE
WARNING: Flaps will not function with Master Switch off
ELECTRICAL SMOKE OR FIRE Procedure
1. Master Switch ..………………………………………………..………..…………..…
OFF
2. Cabin Vents ………………………..………………………………………………….
CLOSED
3. Cabin Heat and Cabin Air Control Knobs ……………………………………… OFF
4. All Other Switches (Except Magnetos) ………………..………………………..
OFF
5. Fire Extinguisher (if installed) …………………………….…………….. ACTIVATE
WARNING: Ventilate Cabin after discharging extinguisher in closed cabin
If fire appears to be out and electrical power is necessary for
continuation of flight:
6. Circuit Breakers ……………….... CHECK for faulty circuit – DO NOT RESET
7. Master Switch ………………………………………………….……………..…….…….. ON
8. Avionics Power Switches …………………………………….………….……..….... ON
9. Radio / Electrical Switches ……………….………………..……………….……….. ON
One at a time, with delay after each until short circuit is localised
10. Cabin Heat & Air Vents ……………………..……………………………….… OPEN*
* When it is ascertained that fire is completely extinguished
WARNING: IF FIRE IS NOT EXTINGUISHED, LAND IMMEDIATELY
IF FIRE IS EXTINGUISHED, LAND AS SOON AS POSSIBLE
CABIN FIRE Procedure
1. Master Switch …..………………………………………………..…………………..… OFF
2. Cabin Heat & Air Vents ……………………..……………………..… OFF / CLOSED
3. Fire Extinguisher (if installed) …………………………….…………….. ACTIVATE
WARNING: Ventilate Cabin after discharging extinguisher in closed cabin
4. Landing (as soon as possible) ……………………………………..……… EXECUTE
Inspect for damage

Table of Contents