1. The compressor is controlled by a pressure switch. It can be stopped
automatically as the pressure increases to the maximum and restarted
as pressure decreases to the minimum. The rated pressure has been
adjusted during the manufacturing process - don’t alter it carelessly.
2. As soon as motor switched off the compressed air in the discharge pipe
should be released through the release valve under the switch. This is
the necessary condition for restart, or the motor will be damaged. The
rated pressure can be adjusted by turning the adjusting bolt of the
PRESSURE ADJUSTMENT
THERMAL RESET SWITCH
This compressor has a thermal overload device.
If the motor gets too hot, the thermal overload device cuts the power
which prevents damage to the motor.
If the thermal overload device operates, let the motor cool down for 5
minutes and push the reset button.
If you start the compressor and the overload cutout operates again, stop
the compressor and disconnect from the power supply and have your
compressor examined by a qualified service agent.
WWW.SGS-ENGINEERING.COM