BEFORE CALLING FOR SERVICE
Check the following points before call-
ing for service.
The unit does not operate
•Checkifthecircuitbreakerhastrippedorthe
fusehasblown.
The unit does not cool effectively
•Checkthelters.Ifdirty,cleanthem.
•Checktheoutdoorunittomakesurenothingis
blockingtheairinletoroutlet.
•Checkthethermostatispropersetting.
•Makesurewindowsanddoorsareclosed
tightly.
The unit does not receive the remote
control signal
•Checkwhethertheremotecontrolbatteries
havebecomeoldandweak.
•Trytosendthesignalagainwiththeremote
controlpointedproperlytowardstheunit’s
signalreceiverwindow.
•Checkwhethertheremotecontrolbatteriesare
installed properly.
Please call for service when the green
OPERATION lamp, the orange TIMER
lamp and/or the blue lamp on the unit
blink.
To describe the malfunction to service,
you may nd out the error code by the
remote control before calling for ser-
vice.
The following conditions do not denote
equipment malfunctions.
UNIT DOES NOT OPERATE
Theunitwillnotoperateifitisturnedonim-
mediatelyafteritisturnedoff.Theunitwillnot
operate immediately after the mode is changed.
Thisistoprotecttheunit.Wait3minutesbefore
operating the unit.
ODORS
Carpet and furniture odors that entered into the
unitmaybesentoutfromtheunit.
CRACKING NOISE
Thissoundisgeneratedbythefrictionoftheunit
expandingorcontractingduetoatemperature
change.
MIST SEEN AT INDOOR AIR OUTLET
Incoolingoperation,thisiscausedbythediffer-
encebetweentheroomairtemperatureandthe
air discharged.
THE OUTDOOR UNIT DOES NOT STOP
Afterstoppingtheoperation,theoutdoorunitwill
rotateitsfanforaboutaminutetocooldownthe
unit.
SWISHING NOISE
Thesoft,swishingnoiseisthesoundofthe
refrigerantowinginsidetheunit.
ODOR EMITTED FROM THE
PLASMACLUSTER AIR OUTLET
Thisisthesmellofozonegeneratedfromthe
PlasmaclusterIongenerator.Theozoneconcen-
tration is very small, posing no adverse effect on
yourhealth.Theozonedischargedintotheair
rapidly decomposes, and its density in the room
willnotincrease.
A LOW BUZZING NOISE
ThisisasoundoftheunitgeneratingPlas-
macluster ions.