3. AE level adjustment (OC mode)
[Input method]
When the PHOTO lamp lights up, press and hold the density
select key for 5 sec, and the AUTO mode lamp will blink and
the adjusted level will be displayed on the exposure level dis-
play.
[Adjustment]
For adjustment, press the density adjustment key too select the
density in 5 steps.
[Terminating method]
Press the density select key, and the model display will turn
from blinking to lighting to terminate the AE level adjustment.
4. AE level adjustment (SPF mode)
[Input method]
While the SPF mode lamp is lighting, when the PHOTO mode
lamp lights up, press and hold the density select key for 5 sec,
and the AUTO mode lamp will blink and the adjusted level will
be displayed on the exposure level display.
[Adjustment]
For adjustment, press the density adjustment key to select the
density in 5 steps.
[Terminating method]
When the density select key is pressed, the mode display will
turn from blinking to lighting to terminate the AE level adjust-
ment.
5. Toner save mode setup and cancel
[Input method]
When the TEST mode lamp lights up, press and hold the den-
sity select key for 5 sec, and the PHOTO mode lamp will turn
from blinking to lighting and the adjusted level will be displayed
on the exposure level display.
[Setup/Cancel]
Press the left key: Level “1” ON, toner save mode setup Press
the right key: Level “5” ON, toner save mode cancel.
[Terminating method]
When the density select key is pressed, the mode display turns
from blinking to lighting to terminate setup.
AL-1250
8-2