AR-6020V SIMULATIONS 6-13
1
30 01 Paper sensor status display
The paper sensor status is displayed with the lamps on the operation panel.
* When each sensor detects paper, the corresponding lamp turns on.
42
01 Developing counter clear
The developer counter data in the EEPROM is cleared and “000” is displayed on the number of copies display.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
02 Developing counter clear Unusable.
43 01
<20/23 CPM>
Fusing temperature setting 1
<Fusing temperature setting 1>
With the simulation executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry..
*1: As the set value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 4, becomes 170 degree C.
*2: As the set value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 0/3, becomes 50 degree C (20 ppm)/
165 degree C (23 ppm) respectively.
*3: As the set value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 6, becomes 180 degree C.
*4: As the set value is increased by 1, the target temperature is increased by 10 degree C.
(See Table 2.) The temperature for the default, 2, becomes 100 degree C.
*5: The corrected temperature to be added to the target temperature varies according to the paper
size. For details, refer to 43-04.
Tabl e 1
Tabl e 2
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents Details of operation
LED Sensor name
INTERRUPT key indicator
SCAN key indicator
ONLINE key indicator
ID CARD COPY key indicator
AUTO indicator
TEXT indicator
PHOTO indicator
Paper exit sensor
Duplex sensor
Paper entry sensor
Bypass tray empty sensor
1st tray paper empty sensor
1st tray empty sensor
Bypass tray paper width sensor
Display
lamp
Contents Setting Display Setup range Reference Default
1 Ready standby TH_UM set value O O Table1 A 5
2 Black-White plain paper TH_UM set value O O Table1 C 4
3 Thin paper TH_UM set value O O Table1 D 3
4 Heavy paper1 TH_UM set value O O Table1 E 6
5 Heavy paper2 TH_UM set value O O Table1 F 6
6 Label paper TH_UM set value O O Table1 G 6
7 OHP TH_UM set value O O Table1 H 6
8 Envelop 1 - 9 TH_UM set value O O Table1 I 6
9 MM prior rotation start TH_UM set value O O Table2 J 2
10 MM prior rotation end TH_EX set value O O 0 - 90 K 3
11 Warm-up complete time O O 0 - 90 L 20
No.
012345678910111213141516
Temperature
(Degree C)
150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230
No.
012345678
Temperature
(Degree C)
80 90 100 110 120 130 140 150 160