AR-6020V SIMULATIONS 6-14
43 01
<26/31 CPM>
Fusing temperature setting 1
<Fusing temperature setting 1>
With the simulation executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry..
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents Details of operation
Display
lamp
Contents Setting Display
Setup
range
Reference
1 Ready standby TH_UM set value O O 70 - 220 A
2 Ready standby TH_US set value O O 70 - 220 B
3 Black-White plain paper TH_UM set value O O 70 - 220 C
4 Black-White plain paper TH_US set value O O 70 - 220 D
5 Fusing motor front rotation start TH-UM set value O O 0 - 200 E
6 Fusing motor front rotation end time O O 0 - 60 F
7 Warm-up complete time O O 0 - 20 G
8 Thin paper TH_UM set value O O 70 - 220 H
9 Thin paper TH_US set value O O 70 - 220 I
10 Heavy paper TH_UM set value O O 70 - 220 J
11 Heavy paper TH_US set value O O 70 - 220 K
12 Label paper TH_UM set value O O 70 - 220 L
13 Label paper TH_US set value O O 70 - 220 M
14 OHP TH_UM set value O O 70 - 220 N
15 OHP TH_US set value O O 70 - 220 O
16 Envelop TH_UM set value O O 70 - 220 P
17 Envelop TH_US set value O O 70 - 220 Q
18 Preheating TH_UM set value O O 70 - 220 R
19 Preheating TH_US set value O O 70 - 220 S
20 TH_UH set value when recovering from preheating O O 70 - 220 T
21 TH_UM set value when Warm-Up at 120 degrees or below O O 70 - 220U
22 TH_US set value when Warm-Up at 120 degrees or below O O 70 - 220V
23 O, P valid time (Timer from Ready state) O O 0 - 255 W
24 TH_UM set value when Warm-Up at 120 degree C or
above
OO70 - 220X
25 TH_US set value when Warm-Up at 120 degree C or above O O 70 - 220 Y
26 R, S valid time (Timer from Ready state) O O 0 - 255 Z
27 FM front rotation start TH_UM when Warm-Up at alpha
degree or above
OO0 - 220AA
28 Warm-Up completion time when Warm-Up at alpha degree
or above
OO0 - 60AB
29 Job approval TH_UM temperature (1) when Warm-Up at
alpha degree or above
OO30 - 220AC
30 Threshold alpha applying U -W O O 1 - 119 AD
31 Job approval TH_UM temperature (1) when Warm-Up at
alpha degree or less
OO70 - 220AE
32 Rear rotation time at the job completion time O O 0 - 60 AF
33 Job approval TH_UM temperature (2) when Warm-Up at
alpha degree or above
OO70 - 220AG
34 Job approval TH_UM temperature (2) when Warm-Up at
alpha degree or less
OO70 - 220AH