AR-6020V SIMULATIONS 6-15
1
1
43
02
<20/23 CPM only>
Fusing temperature setting 2
<Fusing temperature setting 2>
With the simulation executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry..
*1: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 16, becomes 230 degree C.
*2: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 6, becomes 180 degree C.
Table 1
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
03
<20/23 CPM only>
Fusing temperature setting 3
<Fusing temperature setting 3>
With the simulation executed, the current setup values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry.
*1: As the setup value is increased by 1, the target temperature is increased by 10 degree C.
(See Table 2.) The temperature for the default, 3, becomes 110 degree C.
*2: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 2, becomes 160 degree C.
*3: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 1.) The temperature for the default, 0, becomes 150 degree C.
Tabl e 1
Tabl e 2
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents Details of operation
Display
lamp
Contents Setting Display Setup range Reference Default
1 Alarm Stop change TH_US temperature O O Table1 M 16
2 Alarm Stop release TH_US temperature O O Table1 N 6
3 After rotating time when a job is completed O O 0 - 90 O 0
No.
012345678910111213141516
Temperature
(Degree C)
150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230
Display
lamp
Contents Setting Display
Setup
range
Reference Default
1 Preheating TH_UM set value O O Table2 S 2
2
TH_UM set value when Warm-Up at 120 degree C
or below
O O Table1 T 3
3
TH_UM set value when Warm-Up at 120 degree C
or above
O O Table1 Y 0
4
Warm-Up completion time when Warm-Up at alpha
degree C or above
O O 0 - 90 AB 23
5
TH_UM set value when Warm-Up at alpha degree
C or above
O O Table1 AC 2
6 Threshold value alpha when applying the AB to AC. O O 50 - 90 AD 70
No.
012345678910111213141516
Temperature
(Degree C)
150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230
No.
012345678
Temperature
(Degree C)
80 90 100 110 120 130 140 150 160
1