AR-6020V SIMULATIONS 6-16
1
43 04
<20/23 CPM>
Fusing temperature setting 4
<Fusing temperature setting 4>
When this simulation is executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry.
*1: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 3.) The temperature for the default, 5, becomes 5 degree C.
*2: As the setup value is increased by 1, the target temperature is increased by 5 degree C.
(See Table 3.) The temperature for the default, 3, becomes -5 degree C.
*3: Correction temperature from starting a JOB to reaching the JOB initial temperature correction no.
of sheets
*4: Correction temperature from starting a JOB to reaching the JOB latter-half temperature correction
no. of sheets
Tabl e 3
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
<26/31 CPM>
Fusing temperature setting 2
<Fusing temperature setting 2>
With the simulation executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry..
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents Details of operation
Display
lamp
Contents Setting Display
Setup
range
Reference Default
1 Ready standby TH_UM set value [L environment] O O 0 - 99 A 60
2
Black-White plain paper TH_UM set value [L envi-
ronment]
O O 0 - 99 C 55
3 Thin paper TH_UM set value [L environment] O O 0 - 99 D 55
4 Heavy paper1 TH_UM set value [L environment] O O 0 - 99 E 55
5 Heavy paper2 TH_UM set value [L environment] O O 0 - 99 F 55
6 Label paper TH_UM set value [L environment] O O 0 - 99 G 55
7 OHP TH_UM set value [L environment] O O 0 - 99 H 55
8 Envelop 1 - 9 TH_UM set value [L environment] O O 0 - 99 I 55
9
MM prior rotation start TH_UM set value [L environ-
ment]
O O 0 - 99 J 50
10
MM prior rotation end TH_EX set value [L environ-
ment]
O O 0 - 99 K 56
11 Warm-up complete time [L environment] O O 0 - 99 L 50
12
Alarm Stop change TH_US temperature [L environ-
ment]
O O 0 - 99 M 50
13
Alarm Stop release TH_US temperature [L environ-
ment]
O O 0 - 99 N 50
14
After rotating time when a job is completed [L envi-
ronment]
O O 0 - 99 O 50
15 Preheating TH_UM set value [L environment] O O 0 - 99 S 50
16
TH_UM set value when Warm-Up at 120 degree C
or below [L environment]
O O 0 - 99 V 55
17
TH_UM set value when Warm-Up at 120 degree C
or above [L environment]
O O 0 - 99 Y 55
18
Warm-Up completion time when Warm-Up at alpha
degree C or above [L environment]
O O 0 - 99 AB 50
19
TH_UM set value when Warm-Up at alpha degree
C or above [L environment]
O O 0 - 99 AC 55
20
Threshold value alpha when applying the AB to AC.
[L environment]
O O 30 - 70 AD 50
No. 012345678
Temperature
(Degree C)
-20 -15 -10 -5 0 5 10 15 20
Display
lamp
Contents Setting Display
Setup
range
Reference
1 Black-White plain paper duplex TH_UM set value O O 70 - 220 A
2 Black-White plain paper duplex TH_US set value O O 70 - 220 B
3 Applicable paper quantity of Black-White plain paper duplex O O 0 - 255 C
4 Black-White heavy paper duplex TH_UM set value O O 70 - 220 D
5 Black-White heavy paper duplex TH_US set value O O 0 - 200 E
6 Applicable paper quantity of Black-White heavy paper duplex O O 0 - 255 F
1
: ‘19/Oct.