AR-6020V SIMULATIONS 6-17
43
20
<26/31 CPM only>
Fusing temperature setting 3
<Fusing temperature setting 3>
With the simulation executed, the current setup values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
22
<26/31 CPM only>
Fusing temperature setting 4
<Fusing temperature setting 4>
When this simulation is executed, the current set values are displayed.
Switch the set value with [Concentration SW] key and press the [START] key. Then the machine writes the data into
EEPROM and is standing by the sub-code entry.
When the [INTERRUPT] key is pressed at that time, the machine goes into the sub code input standby mode.
When the [CA] key is pressed, the simulation mode is terminated.
Main
code
Sub
code
Contents Details of operation
Display
lamp
Contents Setting Display
Setup
range
Reference
1 Ready standby TH_UM set value O O 1 - 99 A
2 Ready standby TH_US set value O O 1 - 99 B
3 Black-White plain paper TH_UM set value O O 1 - 99 C
4 Black-White plain paper TH_US set value O O 1 - 99 D
5 Fusing motor front rotation start TH-UM set value O O 1 - 99 E
6 Fusing motor front rotation end time O O 1 - 99 F
7 Warm-up complete time O O 1 - 99 G
8 Thin paper TH_UM set value O O 1 - 99 H
9 Thin paper TH_US set value O O 1 - 99 I
10 Heavy paper TH_UM set value O O 1 - 99 J
11 Heavy paper TH_US set value O O 1 - 99 K
12 Label paper TH_UM set value O O 1 - 99 L
13 Label paper TH_US set value O O 1 - 99 M
14 OHP TH_UM set value O O 1 - 99 N
15 OHP TH_US set value O O 1 - 99 O
16 Envelop TH_UM set value O O 1 - 99 P
17 Envelop TH_US set value O O 1 - 99 Q
18 Preheating TH_UM set value O O 1 - 99 R
19 Preheating TH_US set value O O 1 - 99 S
20 TH_UH set value when recovering from preheating O O 1 - 99 T
21 TH_UM set value when Warm-Up at 120 degrees or below O O 1 - 99 U
22 TH_US set value when Warm-Up at 120 degrees or below O O 1 - 99 V
23 O, P valid time (Timer from Ready state) O O 1 - 99 W
24 TH_UM set value when Warm-Up at 120 degree C or above O O 1 - 99 X
25 TH_US set value when Warm-Up at 120 degree C or above O O 1 - 99 Y
26 R, S valid time (Timer from Ready state) O O 1 - 99 Z
27 FM front rotation start TH_UM when Warm-Up at alpha
degree or above
O O 1 - 99 AA
28 Warm-Up completion time when Warm-Up at alpha degree
or above
O O 1 - 99 AB
29 Job approval TH_UM temperature (1) when Warm-Up at
alpha degree or above
O O 1 - 99 AC
30 Threshold alpha applying U -W O O 1 - 99 AD
31 Job approval TH_UM temperature (1) when Warm-Up at
alpha degree or less
O O 1 - 99 AE
32 Rear rotation time at the job completion time O O 1 - 99 AF
33 Job approval TH_UM temperature (2) when Warm-Up at
alpha degree or above
O O 1 - 99 AG
34 Job approval TH_UM temperature (2) when Warm-Up at
alpha degree or less
O O 1 - 99 AH
Display
lamp
Contents Setting Display
Setup
range
Reference
1 Black-White plain paper duplex TH_UM set value O O 1 - 99 A
2 Black-White plain paper duplex TH_US set value O O 1 - 99 B
3 Applicable paper quantity of Black-White plain paper duplex O O 1 - 99 C
4 Black-White heavy paper duplex TH_UM set value O O 1 - 99 D
5 Black-White heavy paper duplex TH_US set value O O 1 - 99 E
6 Applicable paper quantity of Black-White heavy paper duplex O O 1 - 99 F
1