EasyManua.ls Logo

Sharp AY-X36RU - Capacity Variation Ratio According to Temperature

Sharp AY-X36RU
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
AY-X36RU
AE-X36RU
2. Capacity Variation Ratio According to Temperature
90 95 100 105 110
5 10 15 20 25 30 35
40
45 50
100
105
95
90
85
80
75
70
65
60
55
50
Outdoor temp. (˚F)
Capacity ratio (%)
110
100
90
80
70
60
50
40
Outdoor temp. (˚F)
Capacity ratio (%)
Conditions
Indoor:
Pipe length :
24.6ft
DB 80.6°F
WB66.2
°F
Condition
Indoor:DB 70°F
Indoor air flow: Super High
Indoor air flow: Super High
Pipe length:24.6ft
Cooling
Heating
3. Cooling and Heating Data Sheet in Rated Frequency
Cooling:
Rated cooling condition
(°F) (DB/WB)
Pressure of gas pipe connect-
ing indoor and outdoor unit
Inlet and outlet pipe temper-
ature of heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution (rps)
Indoor Outdoor P (MPa) T1 (°F) T2 (°F)
80/66.9 95/- 0.9 ~1.0 46.8 to 52.8 127 to 96.8 Supper High High 67
Heating:
Rated cooling condition
(°F) (DB/WB)
Pressure of gas pipe connect-
ing indoor and outdoor unit
Inlet and outlet pipe temper-
ature of heat exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution (rps)
Indoor Outdoor P (MPa) T1 (°F) T2 (°F)
70/- 19.94/19.04 3.5 ~3.8 134.4 to 102 36 to 39 Supper High High 61
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.

Other manuals for Sharp AY-X36RU