LC-60/70LE650U/C6500U/LE657U,LC-60/70LE755U/LE757U/LE857U/C7500U
2 – 1
LC-60LE650U
Service Manual
 
CHAPTER 2. SCHEMATIC DIAGRAM
[1] DESCRIPTION OF SCHEMATIC DIAGRAM
1. VOLTAGE MEASUREMENT CONDITION:
1) The voltages at test points are measured on exclusive AC adaptor and the stable supply voltage of AC 120V. Signals are fed by a color bar signal gener-
ator for servicing purpose and the above voltages are measured with a 20k ohm/V tester.
2. INDICATION OF RESISTOR & CAPACITOR:
RESISTOR
1) The unit of resistance "Ω" is omitted. 
(K=kΩ=1000Ω, M=MΩ).
2) All resistors are ± 5%, unless otherwise noted. 
(K= ± 10%, F= ± 1%, D= ± 0.5%)
3) All resistors are 1/16W, unless otherwise noted. 
CAPACITOR
1) All capacitors are µF, unless otherwise noted.  
(P=pF=µµF).
2) All capacitors are 50V, unless otherwise noted. 
CAUTION:
This circuit diagram is original one, therefore there may be a slight 
difference from yours.
SAFETY NOTES:
1) DISCONNECT THE AC PLUG FROM THE AC OUTLET 
BEFORE REPLACING PARTS.
2) SEMICONDUCTOR HEAT SINKS SHOULD BE REGARDED AS 
POTENTIAL SHOCK HAZARDS WHEN THE CHASSIS IS 
OPERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH " " ( ) ARE IMPORTANT 
FOR MAINTAINING THE SAFETY OF THE SET. BE SURE TO 
REPLACE THESE PARTS WITH SPECIFIED ONES FOR MAIN-
TAINING THE SAFETY AND PERFORMANCE OF THE SET.
AVIS DE SECURITE IMPORTANT:
LES PIECES MARQUEES " " ( ) SONT IMPOR-
TANTES POUR MAINTENIR LA SECURITE DE L'APPAREIL.
NE REMPLACER CES PIEDES QUE PAR DES PIECES DONT LE 
NUMERO EST SPECIFIE POUR MAINTENIR LA SECURITE ET 
PROTEGER LE BON FONCTIONNEMENT DE L'APPAREIL.