(7) When the surface becomes dusty, please wipe gently with absorbent cotton 
or other soft materials like chamois soaks with petroleum benzine. 
Normal-hexane is recommended for cleaning the adhesives used to attach 
front / rear polarizers. Do not use acetone, toluene and alcohol because 
they cause chemical damage to the polarizer. 
(8) Wipe off saliva or water drops as soon as possible. Their long time contact 
with polarizer causes deformations and color fading. 
(9) Do not open the case because inside circuits do not have sufficient strength. 
 
9-2. Operating Precautions 
(1) The spike noise causes the mis-operation of circuits. It should be lower than 
following voltage: 
V=±200mV(Over and under shoot voltage) 
(2) Response time depends on the temperature.(In lower temperature, it 
becomes longer.) 
(3) Brightness depends on the temperature. (In lower temperature, it becomes 
lower.) And in lower temperature, response time (required time that 
brightness is stable after turned on) becomes longer. 
(4) Be careful for condensation at sudden temperature change. Condensation 
makes damage to polarizer or electrical contacted parts. And after fading 
condensation, smearor spot will occur. 
(5) When fixed patterns are displayed for a long time, remnant image is likely to 
occur. 
(6) Module has high frequency circuits. Sufficient suppression to the 
electromagnetic interference shall be done by system manufacturers. 
Grounding and shielding methods may be important to minimize the 
interference. 
(7) Please do not give any mechanical and/or acoustical impact to LCM. 
Otherwise, LCM can’t be operated its full characteristics perfectly. 
(8) A screw which is fastened up the steels should be a machine screw. (if not, 
it causes metallic foreign material and deal LCM afatal blow) 
(9) Please do not set LCD on its edge. 
 
9-3. Electrostatic Discharge Control 
Since a module is composed of electronic circuits, it is not strong to electrostatic 
discharge. Make certain that treatment persons are connected to ground 
through wrist band etc. And don’t touch interface pin directly.