LC-90LE740X
5 – 1
LC-90LE740X
Service Manual
CHAPTER 5. ADJUSTMENT
[1] ADJUSTMENT PROCEDURE
Main unit supplied as service unit was adjusted on some item.
However, W/B adj is not finished because it needs to be done by final set condition. So the main unit is in the adjustment condition when it is supplied
and K mark is shown up in display when you use it. After finishing Factory setting, K -mark disappear so please do it as following ADJUSTMENT
PROCUDURE.
The adjustment values are set to the optimum conditions at the factory before shipping. If a value should become improper or an adjustment is
required due to part replacement, make an adjustment according to the following procedure.
1. After replacement of any PWB unit and/or IC for repair, please note the following.
When replacing the following units, make sure to prepare the new units loaded with updated software.
When replacing the LCD control PWB, perform the VCOM adjustment.
2. Upgrading of each microprocessor software
CAUTION: Never “POWER OFF” the unit when software upgrade is ongoing.
Otherwise the system may be damaged beyond recovery.
2.1. Software version upgrade
The model employs the following software.
Main software (please use a software version after LEON_LE740X_xxx.USB).
Monitor microprocessor software (please use a software version after LEONSUBxxx.SMB.)
The main software, monitor microprocessor software can be upgraded by using a general-purpose USB Memory.
The followings are the procedures for upgrading, explained separately for the main software, monitor microprocessor software.
2.2. Main software version upgrade
2.2.1 Get ready before you start
USB Memory of 128MB or higher capacity.
PC running on Windows 98/98SE/ME/2000/XP operating system.
USB Memory reader/writer or PC with a USB port.
The file system of a USB memory is FAT. (FAT32 supports)
Use the USB memory without other functions. (lock and memory reader...etc)
2.2.2 Preparations
To upgrade the main software, it is necessary to get ready the USB Memory for version upgrade before you start.
Follow the steps below and create the USB Memory for version upgrade.
1. Copy the file LEON_LE740X_xxx.USB for version upgrade to the root directory (folder) of the USB Memory.
NOTE: In the USB Memory drive, do not store other folders or unrelated files, or more than one file for version upgrade.
Now the USB Memory for version upgrade is ready.
MAIN Unit: DKEYMF953FMJ6