MX-5001N SIMULATION 6 – 66
OTHER TN/TC TN HUD AREA Toner control display humidity area 1 - 14 9
TN HUD DATA Toner control display humidity AD value 0 - 1023 0
TC TMP AREA Transfer display temperature area 1 - 9 4
TC TMP DATA Transfer display temperature AD value 0 - 1023 0
TC HUD AREA Transfer display humidity area 1 - 9 4
TC HUD DATA Transfer display humidity AD value 0 - 1023 0
MD HUD AREA Membrane decrease display humidity area 1 - 14 9
MD HUD DATA Membrane decrease display humidity AD
value
0 - 1023 0
DRUM MD K STEP Drum membrane decrease correction STEP
display (KCMY)
0 - 4 0
MD C STEP
MD M STEP
MD Y STEP
MD K DRUM COUNTER Membrane decrease drum traveling
distance area (KCMY)
0 - 20 0
MD C DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
VG MD K REVISE(VG) : L *** M *** Drum membrane decrease grid voltage
correction display (KCMY)
0 - 255 0
MD C REVISE(VG) : L *** M ***
MD M REVISE(VG) : L *** M ***
MD Y REVISE(VG) : L *** M ***
LD MD K REVISE(LD) : L *** M *** Drum membrane decrease laser power
voltage correction (KCMY)
0 - 255 0
MD C REVISE(LD) : L *** M ***
MD M REVISE(LD) : L *** M ***
MD Y REVISE(LD) : L *** M ***
HV MD K REVISE(HV) : L *** M *** High density membrane decrease
environment GB correction display (KCMY)
0 - 255 0
MD C REVISE(HV) : L *** M ***
MD M REVISE(HV) : L *** M ***
MD Y REVISE(HV) : L *** M ***
CP MD K REVISE(CP) : L *** M *** Drum membrane decrease environment
grid voltage correction display (KCMY)
0 - 255 0
MD C REVISE(CP) : L *** M ***
MD M REVISE(CP) : L *** M ***
MD Y REVISE(CP) : L *** M ***
DL MD K REVISE COL (DL): L *** M *** Drum membrane decrease discharge light
quantity correction (%)
0 - 100 50
MD C REVISE COL (DL): L *** M ***
MD M REVISE COL (DL): L *** M ***
MD Y REVISE COL (DL): L *** M ***
DL EV MD K REVISE COL (DL EV): L *** M *** Drum membrane decrease environment
discharge light quantity correction (%)
-100 - 100 0
MD C REVISE COL (DL EV): L *** M ***
MD M REVISE COL (DL EV): L *** M ***
MD Y REVISE COL (DL EV): L *** M ***
CRUM DESTINATION Machine side management CRUM
destination (Main unit data)
--
MODEL TYPE Machine model type 0 - 1 0
CRUM DEST_K CRUM destination (CRUM data) - -
CRUM DEST_C
CRUM DEST_M
CRUM DEST_Y
CNT PROCON COUNT HV High density process control number of
executions
0 - 99999999 0
PROCON COUNT HT Half tone process control number of
executions
0 - 99999999 0
Mode Item/Display (*: Correction value) Content Display range
Default
value
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
352&21'$7$',63352&211250$/01250$//
%/$&.B3*%B'9B
&<$1B3*%B'9B
0$*(17$B3*%B'9B
<(//2:B3*%B'9B
%/$&.B0*%B'9B%/$&.B/*%B'9B
&<$1B0*%B'9B&<$1B/*%B'9B
0$*(17$B0*%B'9B0$*(17$B/*%B'9B
<(//2:B0*%B'9B<(//2:B/*%B'9B
27+(5&3<351