MX-5001N  SELF DIAG AND TROUBLE CODE  7 – 9
 
E7-08 MFP memory compatibility error 
(MFP PWB)
 
E7-09 Wrong memory size 
(Std./Ext. memory) (MFP PWB)
 
E7-10 Shading error (Black correction)
 
E7-11 Shading error (White correction)
 
E7-14 CCD-ASIC error
 
E7-20 LSU laser detection error (K)
 
E7-21 LSU laser detection error (C)
 
E7-22 LSU laser detection error (M)
 
E7-23 LSU laser detection error (Y)
Trouble content
Detail MFP
Cause A DIMM of different specifications is installed to the 
MFP memory slot.
DIMM trouble.
Check & Remedy Check the installed DIMM.
Replace the DIMM.
Trouble content
Detail MFP
Cause A DIMM which is not 512MB is inserted into the 
default slot.
DIMM trouble.
Insufficient memory size.
Check & Remedy Replace the DIMM.
Trouble content
Detail SCU
Cause Abnormality in the CCD black scan level when the 
scanner lamp is turned OFF.
Improper installation of the harness to the CCD unit.
CCD unit abnormality.
SCU PWB abnormality.
Check & Remedy Check connection of the harness to the CCD unit.
Check the CCD unit.
Check the SCU PWB.
Trouble content
Detail SCU
Cause Abnormality in the CCD white reference plate scan 
level when the scanner lamp is turned ON.
Improper installation of the harness to the CCD unit.
Dirt on the mirror, lens, and the reference white plate.
Scanner lamp lighting trouble.
CCD unit abnormality.
SCU PWB abnormality.
Check & Remedy Check connection of the harness to the CCD unit.
Check connection of the harness to the scanner 
lamp unit.
Clean the mirror, the lens, and the reference white 
plate.
Check the CCD unit.
Check the SCU PWB.
Trouble content
Detail SCU
Cause SCU PWB trouble.
Check & Remedy Check the SCU PWB.
Replace the SCU PWB.
Trouble content
Detail PCU
Cause Optical axis shift.
Reduced laser power, lighting error, laser diode 
trouble.
BD PWB trouble.
Harness and connector trouble between the LD/BD 
PWB and the LSU cnt PWB.
Check & Remedy Use SIM61-1 to check the operation of the LSU.
Check the PWB and connection of the harness in the 
LSU.
Replace the LSU.
Trouble content
Detail PCU
Cause Reduced laser power, lighting error, laser diode 
trouble.
Harness and connector trouble between the LD PWB 
and the LSU cnt PWB.
Check & Remedy Use SIM61-1 to check the operation of the LSU.
Check the PWB and connection of the harness in the 
LSU.
Replace the LSU.
Trouble content
Detail PCU
Cause Reduced laser power, lighting error, laser diode 
trouble.
Harness and connector trouble between the LD PWB 
and the LSU cnt PWB.
Check & Remedy Use SIM61-1 to check the operation of the LSU.
Check the PWB and connection of the harness in the 
LSU.
Replace the LSU.
Trouble content
Detail PCU
Cause Reduced laser power, lighting error, laser diode 
trouble.
Harness and connector trouble between the LD PWB 
and the LSU cnt PWB.
Check & Remedy Use SIM61-1 to check the operation of the LSU.
Check the PWB and connection of the harness in the 
LSU.
Replace the LSU.