MX3500N SIMULATION 7 – 55
43-32
Purpose
Operation setting
Function (Purpose)
Used to make various settings of the com-
pulsory operations of the web cleaning at a
job end.
Section
Fusing
Item
Operation
Operation/Procedure
1) Select the item according to the adjustment content with [↑] [↓]
buttons.
2) Enter the adjustment value with 10-key.
3) Press [OK] button. (The set value is saved.)
<Set items>
44
44-1
Purpose
Setting
Function (Purpose)
Used to set whether the correction func-
tions of the image forming (process) sec-
tion are enabled or not.
Section
—
Item
—
Operation/Procedure
1) When the machine enters Simulation 44-01, the currently set
button is highlighted.
Set the item to be set to the normal display.
(Two or more items can be selected.) When an item is
selected, its button is highlighted. When the highlighted button
is pressed again, it returns to the normal display.
2) When [EXECUTE] button is pressed, the current set value is
saved to EEPROM and RAM. After completion of setting,
[EXECUTE] button returns to the normal display.
<Set items>
*1: The transfer efficiency fluctuation is corrected with temperature
and humidity (absolute moisture). YES/NO setting. Transfer
high output voltage correction.
Item Display Item
Set
range
Default
value
A JOB END
COMP
ACT
CHECK
YES Conditions for
compulsory
operations of
the fusing web
motor at a job
end.
Allow 0 to
1
01
NO Inhibit 1
B JOB END COMP
ACT INTERVAL
Interval of the print
quantity for compulsory
operations of the fusing
web motor at a job end.
1 to
200
100
C JOB END COMP
ACT CNT
Count number of
compulsory operations
of the fusing web motor
at a job end.
1 to 5 1
0
A:
A㧦 0
B㧦100
C㧦 1
㧧
JOB END COMP ACT CHECK
㧧
JOB END COMP ACT INTERVAL
㧧
JOB END COMP ACT CNT
SIMULATION NO.43㧙32
JOB END WEB CLEANING COMPULSORY CHECK
0
㨇 0㨪 1 㨉
OK
TEST
CLOSE
Display Content Set range
Default
value
HV Normal operation high-
density process control YES/
NO setting
Normal
(Inhibit: 1: NO)
Highlighted
(Allow: 0: YES)
Allow
HT Normal operation half-tone
process control YES/NO
setting
Allow
TC Transfer output correction
YES/NO setting *1
Allow
MD VG Membrane decrease grid
voltage correction YES/NO
setting
Allow
MD LD Membrane decrease laser
power voltage correction
YES/NO setting
Inhibit
MD EV Membrane decrease
environment grid voltage
correction YES/NO setting
Allow
MD DL Membrane decrease
discharge light quantity
correction YES/NO setting
Normal (Inhibit:
1: NO)
Highlighted
(Allow: 0: YES)
Allow
MD DL EV Membrane decrease
environment discharge light
quantity correction YES/NO
setting
Inhibit
TN_HUM Toner density humidity
correction YES/NO setting
Allow
TN_AREA Toner density area correction
YES/NO setting
Allow
TN_LIFE Toner density life correction
YES/NO setting
Allow
TN_COV Toner density print rate
correction YES/NO setting
Allow
TN_PROCO
N
Toner density process control
correction YES/NO setting
Allow
TN_ENV Toner density environment
correction YES/NO setting
Allow
TN_DRIP Toner density correction,
unconditional supply YES/
NO setting
Allow
TN_SPEND Toner compulsory
consumption mode YES/NO
setting
Allow
PHT 1Pixel half-tone process
control correction YES/NO
setting
Inhibit
AR_AUTO Auto resist adjustment YES/
NO setting
Allow
AR_ERROR Error check YES/NO setting
during auto resist adjustment
Allow
DM_PHASE Drum phase alignment YES/
NO setting
Allow
SENSITIVITY Toner density correction
YES/NO setting
Inhibit
PRT_HT Half tone process control
printer correction feedback
Enable/Disable setting
Allow