MX3500N SIMULATION 7 – 63
<Display item and content description>
<Toner density>
<Details of toner density sensor reference value correction>
<Details of toner density sensor control voltage correction>
* When the correction for the developer counter (life) or the humidity correction is inhibited (OFF) in SIM 44-01, the correction level is dis-
played as "0."
Display item Item content
Set
range
Default
value
TONER DEN_LT(M) Current toner density sensor output value
(final value) at middle speed (KCMY)
1 to 255 129
TONER DEN_ST(M) Current toner density reference value
(including all the correction values) at
middle speed (KCMY)
128
TONER DEN_LT(L) Current toner density sensor output value
(final value) at low speed (KCMY)
129
TONER DEN_ST(L) Current toner density reference value
(including all the correction values) at low
speed (KCMY)
128
TONER DEN_LT(H)
(MX-4500N/4501N)
Current toner density sensor output value
(final value) at high speed (K)
129
TONER DEN_ST(H)
(MX-4500N/4501N)
Current toner density reference value
(including all the correction values) at
high speed (K)
128
Display item Item content Content description Set range
Default
value
AUTO DEVE (M) Automatic developer adjustment value
(at middle speed)
Sensor output value after execution of SIM 25-02 (at middle speed)
(KCMY)
1 to 255 128
ALL(M) All correction reference value (at middle
speed)
Correction reference value (at middle speed) used to calculate all
the correction values for auto developer adjustment value (KCMY)
AUTO DEVE (L) Automatic developer adjustment value
(at low speed)
Sensor output value after execution of SIM 25-02 (at low speed)
(KCMY)
ALL(L) All correction reference value (at low
speed)
Correction reference value (at low speed) used to calculate all the
correction values for auto developer adjustment value (KCMY)
AUTO DEVE(H)
(MX-4500N/4501N)
Automatic developer adjustment value
(at high speed)
Sensor output value after execution of SIM 25-02 (at high speed)
(K)
ALL(H)
(MX-4500N/4501N)
All correction reference value (at high
speed)
Correction reference value (at high speed) used to calculate all the
correction values for auto developer adjustment value (K)
AREA Area correction value Correction value for environment area (K) –127 to 127 0
HUD Humidity correction value Correction value for humidity change (K)
PRINT RATE Print rate correction value Correction value for document print rate (K)
PROCON Process control correction value Correction value for high density process control result (K)
LIFE Life correction value Correction value for developer life (K)
SENSITIVITY Sensitivity correction value Correction for toner density sensor sensitivity (K) 1 to 999 500
Display item Item content Content description Set range
Default
value
AUTO DEVE VO(M) Automatic developer adjustment control
voltage (at middle speed)
Sensor control voltage value (at middle speed) after executing SIM
25-02 (KCMY)
1 to 255 128
ALL VO(M) All correction reference control voltage
(at middle speed)
Control voltage reference value (at middle speed) used to calculate
all the correction values for auto developer adjustment value
(KCMY)
AUTO DEVE VO(L) Automatic developer adjustment control
voltage (at low speed)
Sensor control voltage value (at low speed) after executing SIM 25-
02 (KCMY)
ALL VO(L) All correction reference control voltage
(at low speed)
Control voltage reference value (at low speed) used to calculate all
the correction values for auto developer adjustment value (KCMY)
AUTO DEVE VO(H)
(MX-4500N/4501N)
Automatic developer adjustment control
voltage (at high speed)
Sensor control voltage value (at high speed) after executing SIM
25-02 (K)
ALL VO(H)
(MX-4500N/4501N)
All correction reference control voltage
(at high speed)
Control voltage reference value (at high speed) used to calculate
all the correction values for auto developer adjustment value (K)
AREA VO Area correction control voltage Control voltage correction value for environment area (KCMY) –127 to 127 0
HUD VO Humidity correction control voltage Control voltage correction value for humidity change (KCMY)
PRINT RATE VO Print rate correction control voltage Control voltage correction value for document print rate (KCMY)
PROCON VO Process control correction control
voltage
Control voltage correction value for high density process control
result (KCMY)
LIFE VO Life correction control voltage Control voltage correction value for developer life (KCMY)
SENSITIVITY VO Sensitivity correction control voltage Control voltage correction value for toner density sensor sensitivity
(KCMY)
1 to 999 500
ENV VO Environment correction control voltage Control voltage correction value under high temperature
environment (KCMY)
–127 to 127 0