MX3500N SIMULATION 7 – 67
3) When [OK], [↑], [↓] button, [COLOR], or [BLACK] key is
pressed, the current set data are saved to EEPROM and RAM.
<Set range and default value of each setup>
* A – H display: "Item name: Detail display."
Example: SW ON:YES
44-29
Purpose
Setting
Function (Purpose)
Enable/disable of the half tone correction
during each job is switched.
Section
Process
Item
Operation
Operation/Procedure
1) Select the set item with [↑] and [↓] buttons.
The highlighted set value is switched and the value is dis-
played in the setting area.
* If there is any item over [↑], an active display is made and
item is shifted.
If there is no item over [↑], the display grays out and the
operation is invalid.
If there is any item under [↓], an active display is made and
item is shifted.
If there is no item over [↓], the display grays out and the
operation is invalid.
2) Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3) When [OK], [↑], [↓] button, [COLOR], or [BLACK] key is
pressed, it is highlighted and the current set data are saved to
EEPROM and RAM.
<Set item description: JOB kinds>
* The actual display is "Display item: Set range."
Example: COPY:HV → PHT → HT
Item Display Content Set range Default value
A Process control
execution YES/NO
setting
SW ON YES When supplying the power (when canceling sleep.) Allowed 0 to 1 0 0
NO Inhibited 1
B 24H YES When READY (sleep setting) is kept for 24H or more Allowed 0 to 1 0 0
NO Inhibited 1
C HUM YES The temperature and humidity in the machine are monitored
every 2 hours (which can be set with Item I), and they are more
than the specified level (more than the set value of item 10)
compared with the previous process control.
Allowed 0 to 1 0 0
NO Inhibited 1
D REV1 YES When the power is supplied, and when the accumulated
traveling distance of BK or M position drum unit reaches a
certain level.
Allowed 0 to 1 0 0
NO Inhibited 1
E REV2 YES When the accumulated traveling distance of BK or M position
drum unit reaches a certain level from the previous density
correction.
Allowed 0 to 1 0 0
NO Inhibited 1
F INITIAL YES When warming up after clearing the counter of OPC drum and
the developing unit.
Allowed 0 to 1 0 0
NO Inhibited 1
G PIX YES When one of the accumulated toner counts for each colors
reaches over the specified count from the previous high density
correction.
Allowed 0 to 1 0 1
NO Inhibited 1
H HUM_LIMIT YES The set conditions of item C are added to the set conditions of
items A to G.
Allowed 0 to 1 0 1
NO Inhibited 1
I BK ONLY YES BK process control execution setting when monochrome
printing is continued
Allowed 0 to 1 0 0
NO Inhibited 1
J HUM HOUR Item C temperature/humidity monitor monitoring time interval setting (H:
Hour)
1 to 24 2
K HUM_DIF Specified value of area difference compared with that in the previous process
control execution of item C
1 to 9 2
L BK_RATIO Setting of the zoom ratio (%) of BK position OPC drum traveling distance of
item E
1 to 999 20
M M_RATIO Setting of the zoom ratio (%) of M position OPC drum traveling distance of
item E
1 to 999 20
N PIX_RATIO Pitch count zoom ratio setting (%) 1 to 999 100
O COLOR BORDER Setting of the magnification ratio (%) at the upper limit of the M position
photoconductor traveling distance when BK process control is executed
1 to 999 20
0