PN-465U CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTION
2 – 23
• Initial values of the AV system input mode
12) Select “OK” with [1] [3] buttons, and press [MENU] button.
The WHITE BALANCE SETTING menu is terminated.
13) Perform the WHITE BALANCE setting read procedures to check
that all settings have been properly changed.
3-6. WHITE BALANCE SETTING READ TOOL
OPERATING PROCEDURE
(1) White Balance setting read tool operating conditions
The operating conditions of the White balance setting read tool of the
information display are as follows.
The required RS-232C cable is as shown below. Connect the PC’s
COM port and the RS-232C input terminal of the display.
RS-232C cable: Straight cable (D-Sub 9 pin female - female)
(2)
Installing the White Balance setting read tool
The White Balance setting read tool is provided as the compression file
of “PN465_InfoDispWhiteBalance.zip.”
Decompress “PN465_InfoDispWhiteBalance.zip,” and the execution file
of “InfoDispWhiteBalance.exe” and “InfoDispWhiteBalance.ini” is gener-
ates. Copy “InfoDispWhiteBalance.exe” and “InfoDispWhiteBalance.ini”
to an optional directory and execute “InfoDispWhiteBalance.exe”.
(3)
White Balance setting read tool operating procedures
The procedures to read the White Balance setting by using the White
Balance setting read tool are as follows:
1) Select “PN-465 Series” on the column of Model Name.
2) Select a COM port to be used on the column of COM port.
3) Turn on the power of the LCD monitor.
4) Press [READ] button.
5) When reading of all the setting items is completed, the set value is
displayed.
The data acquisition log is displayed on the left lower section of the
tool.
When “OK” is indicated for all the items as shown below, data acqui-
sition is successfully completed.
• When “Power On ... NG” is displayed:
Check the power status of the connected information display.
When “READ” is executed in the power standby state, the operation
may fail sometimes. Turn ON the power, and press [READ] button
again to read the setting value.
• When “Command Sending Retry Error”, “Nothing Received” is
displayed:
Check to confirm that the PC and the information display are con-
nected with a proper RS-232C cable.
• When “COM Port Open Error” is displayed:
Check to confirm that the COM port is not used by another tool. If the
COM port is used by another tool, terminate the tool and press
[READ] button again to read the setting value.
OS : Windows98SE, Windows2000, WindowsXP
Communication port : RS-232C port recognized as a COM port
(Which allows communication in 9600bps.)
WHITE BALANCE SETTING (AV)
PATTERN
< 9000 K >
LEVEL =>
L1 R: 205 G: 230 B: 209
L2 R: 208 G: 230 B: 212
L3 R: 211 G: 230 B: 215
L4 R: 212 G: 230 B: 217
L5 R: 211 G: 230 B: 218
L6 R: 241 G: 255 B: 246
OK CANCEL RESET
Power On … OK
Change Input to PC … OK
Read PC Level Data … OK
Read PC Red Gain Data … OK
Read PC Green Gain Data … OK
Read PC Blue Gain Data … OK
Change Input to AV … OK
Read AV Level Data … OK
Read AV Red Gain Data … OK
Read AV Green Gain Data … OK
Read AV Blue Gain Data … OK