PN-465U CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTION
2 – 29
[Supplementary descriptions]
Setting the printer port I/O address to 378
1. Open the system of the control panel.
2. Open the hardware tag, and click the device manager button.
3. Click “+” mark on the left of “Port (COM/LPT)”
Check to confirm that there is “ECP printer port (LPT1).
4.
Open the property of the printer port (LPT1), and open the resource
tag.
5. Uncheck “Use automatic settings” and select “Basic setting 0000.
(If “I/O range” is already “0378 - 037F,” there is no need to change.)
In the writing procedures, the copy destination of the files is specified
as “c:\fg”. It may be changed to any folder on the hard disk as far as
all the files are copied to that same folder.
[Canceling write-protect of EDID by the serial command]
[Connection method]
Connect the serial port of PC with the RS-232C input pin of the monitor
by using the straight cable.
1. Execute [START] - [Program] - [Accessory] - [Communication] -
[Hyper terminal].
The window below is displayed. Enter an optional name and press
[OK].
2. The window below is displayed. Select the number of COM con-
nected to the monitor and press OK.
3. The communication setting screen is displayed.
Set as shown below.
4. Set the local echo.
1) Select “Property” in the file menu.
2) Select [Settings] tab and press [ASCII Setup...].

Other manuals for Sharp PN-465U