PN-465U CONNECTION, ADJUSTMENT, OPERATION, AND FUNCTION
2 – 36
4) Click [RUN] button and check to confirm that “PN-465 Temperature
is booted.
5) Select the connected port with “COM Port”.
6) Click [RESET] button to execute resetting.
7) Resetting is completed after a while. Check to confirm that all tab
items are as shown in the figure below. If there is any “ERR” item,
press [RESET] button to execute resetting.
9-3. NOTE FOR USING THE TEMPERATURE MONI-
TOR SETTING TOOL
When an error massage is indicated on the display, check the following
items.
• WhenCommand Sending Retry Error” and “Nothing Received” are
displayed:
Check to confirm that the PC and the information display are prop-
erly connected with the RS-232C cable.
When “COM Port Open Error” is displayed:
Check to confirm that the set COM Port is not used by another tool. If it
is used by another tool, terminate the tool, and execute the procedures
again.