15
[6] REFRIGERATION CYCLE SYSTEM SPECIFICATIONS
R600A PRECAUTIONS1.
• Do not use any refrigerant other than R600a.
• Gas leak testers for HFC-134a, CFC-12, HCFC-22, etc., cannot be used.
A special tool is used for the R600a cycle.
TABLE OF R600A CHARACTERISTICS2.
Refrigerant saturated vapor pressure table R600a
(Unit) Temperature: °C, Pressure: kgf/cm abs
Temperature
Pressure
-20 -15 -10 -5 0 10 15 20 25 30 35 40 45 505
0.74
1.601.340.91 1.11 1.91 2.25 2.64 3.08 3.58 4.13 4.74 5.42 7.006.17
(Unit)Temperature:°C, Pressure: MPa abs
Temperature
Pressure
-20 -15 -10 -5 0 10 15 20 25 30 35 40 45 505
0.073
0.1570.1310.089 0.109 0.187 0.221 0.259 0.302 0.351 0.405 0.465 0.532 0.6860.605
REFRIGERATION CYCLE DIAGRAM3.
Piping Diagram 3-1.
Charge pipe
←(①~⑱)
Show the order of the refrigerant flow
Back
condenser
Dryer
Capillary
tube A
Evaporator
Capillary
tube B
Suction
connector
Suction
pipe
Charge pipe
Compressor
Discharge pipe
ass’y
Side condenser R
Dew proofing condenser
Bottom condenser
Side condenser L
Extension
barrel
Extra
cond.
unit
ass’y