EasyManua.ls Logo

Sharp SJ-XF50X-T

Sharp SJ-XF50X-T
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SJXF50XT
22
FORCED STOPPING OF DOOR ALARM BUZZER2.
* Used when the door switch is faulty.
How to stop
While the door-open buzzer sounds, press the [
冷蔵室
] and [
冷凍室
] buttons simultaneously and hold them for 3
seconds or longer. (The buzzer sounds three times.)
Forced stopping is cancelled automatically 48 hours later.
THERMISTOR CIRCUIT CHECK METHOD3.
A thermistor is a semiconductor for which the resistance value changes as the temperature changes.
This characteristic is used to allow the temperature to be read by a microcomputer.
(Temperature Resistance value Changed to voltage.)
Check Method1-1.
Disconnect the connectors and measure the thermistor resistances.
Determination Method1-2.
If the resistance[1] matches, there is a problem with the electronic circuit board.
If the resistance[1] is different,there is a problem with the harness, connector, or thermistor.
[ 1 ]
CN8
-
CN8
-
CN16
-
CN10
-
CN8
-
CN10
-
Humidity sensor
Ice cubemaker thermistor
F-thermistor
DEF thermistor
R-thermistor
V-thermistor
External air temperature
thermistor
Resistance Value
*1
(Ω)
pins pins
pins
pins
pins
pins
pins
Voltage Value (V)
*2
CN15
-
*1. Disconnect connectors and measure the pins on the wiring side(Ω).
Connector
IC1
+
+5V
[1]
Thermistor
Microcomputer
(A/D)
Table of Thermistor Characteristics1-3.
[1]
- 30.0
- 25.0
- 20.0
- 15.0
- 10.0
- 5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.8
26.1
19.3
14.4
10.9
8.3
6.4
5.0
3.9
3.1
2.5
2.0
1.6
[1]
- 30.0
- 25.0
- 20.0
- 15.0
- 10.0
- 5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.8
26.1
19.3
14.4
10.9
8.3
6.4
5.0
3.9
3.1
2.5
2.0
1.6
[1]
- 30.0
- 25.0
- 20.0
- 15.0
- 10.0
- 5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
83.9
61.2
45.2
33.7
25.5
19.5
15.0
11.7
9.2
7.3
5.8
4.7
3.8
- 30.0
- 25.0
- 20.0
- 15.0
- 10.0
- 5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
[1]
F-thermistor
R-thermistor
V-thermistor
DEF thermistor Humidity sensor
Ice cube maker
thermistor
External air
temperature thermistor
Temperature
Resistance
value
Temperature
Resistance
value
Temperature
Resistance
value
Temperature
Resistance
value
Voltage
value
(kΩ)
(°C)
(kΩ)
(°C)
(kΩ)
(°C)
(kΩ)
25.4
19.5
15.1
11.8
9.4
7.5
6.0
4.9
4.0
3.3
2.7
2.2
1.9
[1]
Resistance
value
(kΩ)
(°C) (V)
-
-
-
-
-
-
-
-
0
10
20
30
40
50
60
70
80
90
100
-
-
0.1
0.4
0.7
1.0
1.3
1.5
1.8
2.1
33.1
25.6
20.0
15.8
12.5
10.0
8.1
2.4
2.7
3.0
Temperature
(°C)
- 30.0
- 25.0
- 20.0
- 15.0
- 10.0
- 5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
Temperature
(°C)

Related product manuals