SJXF50XT
19
Operation in the self-diagnosis mode2)
The compressor is forcedly turned ON. (Excepting a period of defrosting operation and compressor ON delay •
time)
The cooling, condenser and R-fan motors are forcedly turned ON.•
(These motors will be forcedly turned ON even while the compressor is OFF. However, when the door is opened,
the motors other than the condenser fan motor are kept OFF.)
The refrigerator compartment/vegetable compartment PCI fan and the PCI are forcedly turned ON. (However, •
when the door is opened, the PCI and fan are kept OFF.)
When the refrigerator compartment door is opened, the R damper is forcedly closed. When the refrigerator •
compartment door is closed, the R damper is forcedly opened. (Opening/closing the refrigerator compartment
door activates the R damper operation.)
During execution of the self-diagnosis mode, and for 20 minutes after cancellation of this mode, self-diagnosis •
data serial output is executed.
During execution of the self-diagnosis mode, and for 20 minutes after cancellation of this mode, the door-open •
buzzer does not sound.
Operation during self-diagnosis mode, and self-diagnosis display3)
Self-diagnosis data is displayed on the temperature control panel. (Refer to self-diagnosis display [Table 1].)1)
Self-diagnosis display can be switched by operating the temperature control panel buttons.2)
Temperature control panel button Operation
[
冷凍室
] Fault data forward scroll
[
冷蔵室
] Fault data reverse scroll
[
冷凍
] Fault occurrence date forward scroll
To return to the previous
display (Reverse scroll)
To proceed to the next display.
(Forward scroll)
Self-diagnosis (fault) display
To change fault occurrence
date to be displayed.
To indicate occurrence date
of displayed fault.