Connector of pump motor
Pump holder
Screw
Screw
Pump motor
Pump motor MTAG
Note: When installing the pump motor, be sure to insert the con-
nector of the pump motor into the hole of the pump holder.
Otherwise, it cannot be connected to the main harness.
3. Precautions on installation of the tube pump K
1) When installing the tube pump K to the bottom plate, please
first install the tank cover top, the tank cover bottom to the bot-
tom plate.
2) While inserting the claws (3x) of the tube pump K into the holes
(3x) on the tank cover bottom side, please install the tube pump
K onto the bottom plate.
Tube pump K
Claw
Hole
Lower
tank
cover
2. How to remove the tank SW
1) Pull out the tank cover bottom (attached to the tank cover top)
from the opening of the bottom plate.
2) While expanding the claws (2x) which retain the tank SW, re-
move the tank SW from the tank cover bottom.
Claw
Claw
Lower tank cover
Tank SW