XE-A21S PROGRAM MODE
2 – 5
8) DATA PROGRAMMING FOR PLU
There are programmed by below key sequence.
The PLU code is increment automatically when one programming data
of a PLU is set.
And it is operated continuously until depressing the [CA/AT] key.
The JOB is automatically finalized when a maximum PLU code is
programmed.
(Basic programming sequence)
Basic operation consists of below 2 kinds.
<Associate Dept & Price Entry>
<Parameter data Entry>
9) PROGRAMMING OF DEPARTMENTS TO BE
ASSOCIATED WITH PRICE PRESET
DELETE means to be set as a inhibited PLU in memory.
When it is assigned some DEPT for the inhibited (deleted) PLU,
the PLU is set the MRS value except its price.
10) PROGRAMMING OF PLU/SUBDEPT
11) PROGRAMMING OF DEPARTMENT TEXT
Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
MRS = DEPT. xx (xx: DEPT Code)
12) PROGRAMMING OF PLU TEXT
Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
MRS = PLU.xxxx (xxxx: PLU code)
13) PROGRAMMING OF FUNCTION TEXT
Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
MRS = Refer to the following table
XXXX: PLU CODE (1 to 1200)
ZZ: DEPT CODE (1 to 99)
YYYYYY: UNIT PRICE (6 digits)
MRS = DEPT1, Price: 0 (Create: PLU001 to PLU1200)
XXXX: PLU CODE (1 to 1200)
Y: 0 = SUBDEPT, 1 = PLU
MRS = 1 (PLU type)
(DATA)
(Code increment)
PLU DPTn
CA/AT
XXXX
PLU CODE
SBTL
(DATA)
DEPT#
DEPT CODE
DEPT SHIFT
DPTn
(DATA)
(Code increment)
(Code entry)
PLU SBTL
CA/AT
XXXX
PLU CODE
YYYYYY
(Code increment)
(Code entry)
PLU DPTn
DPTn
CA/AT
XXXX
PLU CODE
SBTL
YYYYYY
DEPT#
DEPT CODE
0
ZZ
0
PLU DELETE (INHIBIT)
DEPT SHIFT
Y
(Code entry)
PLU SBTL
CA/AT
XXXX
PLU CODE
0
XX:
Department Code (1 to 99)
(CHATACTERS):
CHARCTER (Max. 12 Characters)
YYY 3
[00] KEY
YYY:
CHARACTER CODE (3 DIGITS)
(or [000] KEY ACCORDING TO PGM PRESET)
XXXX:
PLU CODE (1 to 1200)
(CHARACTERS):
CHARACTER (Max. 12 Characters)
YYY3
[00] KEY
YYY:
CHARACTER CODE (3 DIGITS)
(or [000] KEY ACCORDING TO PGM PRESET)
XX:
FUNCTION CODE (Refer to the FUNCTION LIST)
(CHARACTERS):
CHARACTER (Max. 8 Characters)
YYY 3
[00] KEY
YYY:
CHARACTER CODE (3 DIGITS)
(or [000] KEY ACCORDING TO PGM PRESET)
DPTn (CHARACTERS)
XX
SBTL SBTL 1
CA/TA
DEPT#
DEPT CODE
NO CHANGE
DPTn
DEPT SHIFT
PLU (CHARACTERS)
NO CHANGE
(Code increment)
(Code entry)
XXXX
SBTL SBTL2
CA/AT
PLU CODE
(CHARACTERS)
NO CHANGE
XX
SBTL @/FOR SBTL3
CA/AT