NOTE TO SERVICE PERSONNEL
‘///////////////////
UV-RADIATION
 
PRECAUTION
////////////////////
The light source, metal halide lamp, in the LCD
projector emits small amounts of 
UV-Radiation.
AVOID DIRECT EYE AND SKIN EXPOSURE.
To ensure safety please adhere to the following:
1. Be sure to wear sun-glasses when servicing the
projector with the lamp
turned “on” and the top
enclosure removed.
UV-Radiation
 
and
 
Medium
 
Pressure
Lamp
 
Precautions
1. Be sure to disconnect the AC plug when replacing
the lamp.
2. Allow one hour for the unit to cool down before
servicing.
3. Replace only with same type lamp. Type
CLMPF0044DEOl
 rated 
6OV/125W.
4. The lamp emits small amounts of UV-Radiation,
avoid direct-eye contact.
5. The medium pressure lamp involves a risk of
explosion. Be sure 
tcrfotlow
 installation instructions
described below and handle the lamp with care.
2.
Do not operate the lamp outside of the lamp housing.
3. Do not operate for more than 2 hours with the
enclosure removed.
1
 
w
 
Lamp
 
Replacement
Note:
Since the lamp reaches a very high temperature
during units operation replacement of the lamp should
be done at least one hour after the power has been
turned off. (to allow the lamp to cool off.)
Installing the new lamp, make sure not to touch the
lamp (bulb) replace the lamp by holding its reflector
0.
[Use original replacement only.]
l-k
DANGER 
!
-
 Never turn the power on without
the lamp to avoid electric-shock or damage of the
devices since the stabilizer generates high voltages
at its start.
3