xv-zw99u
I
Replacing the LCDs
With the top cabinet removed
(1) Remove three screws off the output shield.
(2) Disconnect the LCD flat cable from the output PWB connector.
(3) Remove the lock screws “b” and “c”. Detach the R/B adjusting plate or the G adjusting plate together with the
LCD panel.
(4) Separate the LCD panel from the adjusting plate.
(5) Mount a new LCD panel in the reverse order of the above steps (l), (2) (3) and (4).
* Readjust the convergence and focus. Note that the G LCD panel needs no convergence adjustment and has
a small adjustment range in the Z direction,
TOP VIEW
FRONT
Lock screws “c”
Lock screws “c”
SIDE VIEW
FbB adjusting plate
FbB-LCD
FbB-LCD panel
mounting screws
SIDE VIEW
\
G-LCD
G-adjusting plate

Table of Contents