6.7.2. Inner register command (Pr mode)
The following table explains the combinations of POS~POS6, CTRG.
Command
POS6
POS5
POS4
POS3
POS2
POS1
CTRG
Relevant
parameters
P0
0
0
0
0
0
0
PE01
PE02
P1
0
0
0
0
0
1
PE03
PE04
P2
0
0
0
0
1
0
PE05
PE06
~
P50
1
1
0
0
0
1
PF03
PF04
P51
1
0
0
0
1
0
PF05
PF06
~
P63
1
1
1
1
1
1
PF29
PF30
Note1: The state “↑” of CTRG means the transient of open-circuit to short-circuit.
Note2: 0: OFF (POSx-SG is open-circuit), 1ON (POSx-SG is short-circuit), x=1~3
Operate the ON/OFF state of POS1 to POS6 cyclically; user can program a simple motion stroke.
Absolute / incremental position control
The applications of absolute/incremental command are common. Users have to make PA01 valid to
enable these two types. See the table below for parameter setup.
Name
Abbr.
Sign
Control
mode
Description
Control mode option
STY
PA01
ALL
Setting value of Control mode option:
u
z
y
x
x=0position control mode
y=1inner register(absolute type)
y=2inner register(incremental type)
The results between absolute and incremental type are described below.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SDE-010A2 and is the answer not in the manual?

Shihlin electric SDE-010A2 Specifications

General IconGeneral
BrandShihlin electric
ModelSDE-010A2
CategoryDC Drives
LanguageEnglish

Related product manuals