EasyManuals Logo

Shimadzu AA-7000 Series User Manual

Shimadzu AA-7000 Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4
The AA-7000 Series can be upgraded by adding units to allow the system to handle the analysis targets.
The AA
-
7000 Series can be upgraded by adding units to allow the system to handle the analysis targets.
System Configuration can Evolve
with Your Needs
AA-7000 Series supports a wide range of
analysis applications.
Major Fields of Application
Analysis Sensitivities
Concentration limit of detection
(ppm) (ppb)
H
Li NeFONCB
ArClSPAl
Ca Sc Ti Cr Mn Fe Co Ni Cu Zn KrBrSeGa
YZrNbMo
Tc Ru Rh Pd Cd XeTe IIn
Cs Ba La
Fr Ra Ac
Hf Ta W Re Os Ir AuPt Hg RnAtPoBiPbTl
Ce Pr Nd Pm Sm Eu Gd Tb LuYbTmErHoDy
Th Pa U Np Pu Am Cm Bk LrNoMdFmEsCf
He
Ag
a
Sn Sb
Si
V
Be
Na
Rb Sr
Mg
K
Ge As
* May differ according to coexisting substances in the sample.
AA-7000G GFA-7000A
AA-7000G GFA-7000A Auto Sampler System
ASC
*2
Environment
Metals, Semiconductors, Ceramics
Petroleum, Chemicals, Polymers
Seawater, river water, effluent,
sludge, air-borne dust
Metals, minerals, glass,
ceramics, IC chips
Petroleum, oil, catalysts,
chemical products, biodiesel
Blood, animals, plants,
drugs, food products
Medical, Biology, Pharmaceuticals
Flame
Furnace
AA-7000F Manual Burner System
AA
-
7000F
AA-7000F/AAC
AA-7000F/AAC Auto Burner System
GFA
ASC
*1
ASC
*1
*2
*3
AAC
AAC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shimadzu AA-7000 Series and is the answer not in the manual?

Shimadzu AA-7000 Series Specifications

General IconGeneral
ModelAA-7000 Series
TypeAtomic Absorption Spectrophotometer
Wavelength Range185 to 900 nm
DetectorPhotomultiplier tube
Flame MethodAir-Acetylene, Nitrous Oxide-Acetylene
MonochromatorCzerny-Turner mounting
Light SourceHollow Cathode Lamp, Deuterium Lamp
Graphite Furnace MethodAvailable
Background CorrectionDeuterium lamp and self-reversal method
Atomization MethodFlame, Graphite Furnace
Graphite Furnace Heating Program20 steps
Safety FeaturesGas leak detector, flame sensor, over-temperature protection
Optical SystemDouble-beam
Sample IntroductionNebulizer for flame, Autosampler for graphite furnace (optional)
Data OutputUSB
Power SupplyAC 100V to 240V, 50/60 Hz
Spectral Bandwidth0.2, 0.5, 1.0, 2.0 nm (automatic switching)