Gradient Composition Accuracy | ±0.5% |
---|---|
Temperature Stability | ±0.1 °C |
Power Requirements | 100-240 VAC, 50/60 Hz |
Pump Type | Binary or Quaternary Pump |
Flow Rate Accuracy | ±1% or ±1 μL/min, whichever is greater |
Injection Volume | 0.1 to 100 μL (standard) |
Injection Precision | ≤0.25% RSD |
Detector Type | Multiple options available (e.g., UV-Vis, PDA, Fluorescence, etc.) |
Wavelength Range | 190 to 900 nm (for UV-Vis/PDA detectors) |
Temperature Control | Peltier |
Key safety and usage guidelines for operating the system and handling manuals.
Step-by-step guide to powering on the system and launching the analysis software.
Details how to specify and edit analytical parameters for methods.
Details the procedure for performing a single run analysis using one method file.
Describes how to perform batch analysis using LabSolutions.
Details the steps for safely stopping analysis and shutting down the system.
Explains auto-diagnostics and auto-recovery functions for instrument errors.
Details the Auto-Recovery function for recovering from solvent delivery problems.
Describes various pretreatment functions that can be specified for autosamplers.
Describes how to register and discard columns using the column manager and CMD.
Explains the purpose and importance of hardware validation for analytical instruments.
Core maintenance procedure for solvent delivery pumps.
Core maintenance procedure for autosamplers.
Core maintenance procedure for column ovens.
Core maintenance procedure for UV absorbance detectors.
Checks the performance of the entire system.
Provides corrective actions when validation criteria are not met.
Addresses issues where the system does not function properly or analysis is unsuccessful.
Provides solutions for frequently encountered troubleshooting issues.
Troubleshooting steps for unstable solvent delivery pressure.
Diagnoses and resolves issues related to increasing solvent delivery pressure.
Troubleshooting steps when the baseline does not stabilize.
Addresses issues with unstable area reproducibility in analysis results.
Troubleshooting steps for eliminating persistent carryover issues.
Infers problem locations based on hardware status symptoms and suggests corrective actions.
Diagnoses errors based on chromatogram symptoms and suggests corrective actions.
Comprehensive reference for system error codes, messages, causes, and countermeasures.
Lists error codes, messages, causes, and countermeasures for the system controller.
Details error messages, causes, and countermeasures for the solvent delivery pump.
Lists error codes, messages, causes, and countermeasures for the autosampler.
Details error messages, causes, and countermeasures for the column oven.
Lists error codes, messages, causes, and countermeasures for the UV detector.