Shimadzu GC-2014 Series - User Manual

Shimadzu GC-2014 Series
122 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
221-30116
GC-2014
Service Manual
Analytical & Measuring Instruments Division
Shimadzu Corporation

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Shimadzu GC-2014 Series and is the answer not in the manual?

Shimadzu GC-2014 Series Specifications

General IconGeneral
TypeGas Chromatograph
Detector OptionsFID, TCD, ECD, FPD, FTD
DisplayLCD
Injection PortsUp to 3
Column OptionsCapillary, Packed
Data SystemGCsolution software
WeightApprox. 45 kg
Number of DetectorsUp to 4 detectors
Injection PortSplit/Splitless
Power Requirements100-240V AC, 50/60Hz

Summary

CHAPTER 1 INSTALLATION

Installation Space and Environment

Covers required physical space, environmental conditions, and precautionary items.

Power Supply Requirements

Details specified voltage ranges and power capacity needed for the instrument.

Gas Requirements

Outlines gas purity specifications and supply pressure for proper operation.

CHAPTER 2 CONFIGURATION OF GC-2014

GC-2014 Series Configuration Diagrams

Provides assembly configuration charts for various GC-2014 models and their components.

GC-2014 Physical Structure

Details the external appearance and internal component diagrams of the GC-2014.

Electric Circuits and Control Units

Presents block diagrams and circuit schematics for the instrument's electronic systems.

CHAPTER 3 GAS-FLOW CONTROLLER

Gas-Flow Controller Configurations

Shows assembly configuration charts for AFC, Manual Flow Controller, and APC types.

Gas Flow Line Diagrams

Illustrates the gas flow paths for different injection modes.

CHAPTER 4 SAMPLE INJECTION UNIT

Sample Injection Unit Configurations

Details assembly configuration charts for SPL and WBI injection units.

Injection Unit Piping and Details

Explains piping configurations, component diagrams, and heater resistance values.

Packed Dual Injector Assembly

Lists parts and shows assembly diagrams for the Packed Dual Injector.

CHAPTER 5 DETECTOR UNIT

TCD Detector Configuration

Shows parts list and diagram for the Thermal Conductivity Detector (TCD).

FID Detector Configuration

Details parts list and diagram for the Flame Ionization Detector (FID).

ECD Detector Configuration

Illustrates the Electron Capture Detector (ECD) setup and components.

FPD Detector Configuration

Provides assembly diagrams and parts for the Flame Photometric Detector (FPD).

FTD Detector Configurations

Details assembly diagrams and parts for the Flame Thermionic Detector (FTD).

CHAPTER 6 MAINTENANCE PARTS LISTS

GC-2014 Main Unit Parts

Lists part numbers and names for the main GC-2014 unit.

Detector Specific Parts Lists

Lists parts for FID, FPD, FTD, ECD, and TCD detectors.

Injector and Other Parts Lists

Lists parts for Dual Injector and miscellaneous items like AFC and power supply.

CHAPTER 7 TROUBLESHOOTING

Gas and Flow-Rate Troubleshooting

Addresses issues with flow rate control settings for CAR and DetAPC.

Temperature and Detector Troubleshooting

Covers temperature control issues and detector-specific problems (FID, FPD, FTD).

Chromatogram and Data Troubleshooting

Troubleshoots problems with peak output, data format, and signal types.

Other Troubleshooting Problems

Addresses miscellaneous issues like display problems and connection errors.

CHAPTER 8 SERVICE WINDOW

Flow Adjust and Mode Settings

Explains flow rate adjustment, mode settings, and system parameters.

Serial Number and Maintenance Logs

Covers serial number management, maintenance logs, and unit usage times.

Special Function Windows

Describes the initialization for shipment window and other special functions.

CHAPTER 9 APPENDIX

GC-2014 ROM Software Upgrade Procedure

Provides a step-by-step guide for upgrading the GC-2014's firmware via RS-232C.

Related product manuals