Data Sampling Rate | Up to 200 Hz |
---|---|
System Control | LabSolutions software |
Type | HPLC System |
Maximum Operating Pressure | 1034 bar |
Maximum Pressure | 1034 bar |
Flow Rate Range | 0.0001 mL/min |
Flow Rate Accuracy | ±1% or 2 μL/min, whichever is greater |
Flow Rate Precision | <0.06% RSD |
Autosampler Injection Volume | 0.1 to 100 μL |
Detector Types | UV, Vis, PDA, Fluorescence, RID |
Provides a general overview and purpose of the instruction manual.
Lists other manuals and documentation included with the product.
Highlights crucial points regarding manual usage and product handling.
Explains precaution symbols, general notices, and important information.
Details key features of the LC system, including low flow pulsation, gradient modes, auto rinsing, and high-pressure flow.
Lists standard parts included with the instrument, with part numbers and quantities for verification.
Describes optional units available for the instrument, such as gradient kits and mixers.
Identifies and describes the front panel elements, including the operation panel and power button.
Details components located behind the front cover, such as pump heads, drain valve, and leak sensor.
Explains the connectors and switches on the back panel, including remote and PC connections.
Describes mounting holes and the leakage drain outlet on the right side and bottom of the instrument.
Explains the operation panel layout, display area, LEDs, and direct keys for instrument control.
Describes the information displayed on the initial screen, including flow rate, pressure, and status indicators.
Details the function of each key in the operation area, including pump, concentration, run, and purge keys.
Guides on setting flow rate, pressure limits, and compressibility for basic operation.
Covers preparation, constant flow, and constant pressure delivery modes.
Overview of instrument screens and how to navigate between them.
Explains screens for monitoring instrument status, flow, pressure, and diagnostics.
Accesses auxiliary functions for parameter settings and operations, organized into groups.
Accesses validation and instrument information, including product details and maintenance logs.
Guides on creating automated sequences for solvent delivery using time programs.
Procedure for setting up and performing deliveries in low-pressure gradient mode.
Details on connecting and configuring the instrument with a system controller.
Information on connecting external devices via input/output terminals.
Necessity of periodic inspections for safe and proper instrument use.
Covers removal/installation of panel covers, filter holders, and pump heads.
Procedures for replacing plunger seals, backup rings, and diaphragms.
Covers rinsing, replacing check valves, and inspecting/replacing line and suction filters.
Procedures for replacing drain valve, air filter, cleaning leak tray, and exterior.
Specific technical parameters for the LC-40D X3 CL model, including flow rate and pressure.
Specific technical parameters for the LC-40D XR CL model, including flow rate and pressure.
Specifications for high-pressure and low-pressure gradient systems.
Various other technical specifications, including operating temperature, dimensions, and power supply.
Lists all parts required for maintenance, including consumables and replacement parts.