Explains the function of each key on the balance during weighing and menu selection.
Guidelines for selecting a suitable location, considering power supply and environmental factors.
Step-by-step guide for installing the balance, including handling transportation screws and leveling.
Procedure for connecting the AC adapter and powering on the balance, including self-check messages.
Instructions for performing span calibration, essential for accurate weighing after moving the balance.
Detailed steps for performing basic weighing operations, including taring and reading the display.
Common issues and solutions for the WindowsDirect communication function.
Explanation of why and when calibration is required for accurate weighing.
Procedures for executing span calibration and calibration checks using built-in or external weights.
Options for selecting different calibration types, including PSC and Clock-CAL.
Using the bar graph and modes for checkweighing, target setting, and judgment of pass/fail.
Guide on using the Piece Counting function, including setting the sample quantity and unit weight.
Configuration of automatic data output based on various conditions like loading or stability.
Enabling automatic zeroing when the displayed value is within the Zero Range and stability is detected.
Procedure for measuring the specific gravity of solids using the balance and a specific gravity kit.
Method for calculating liquid density by measuring a reference solid in air and the sample liquid.
Explains the function of each key on the balance during weighing and menu selection.
Guidelines for selecting a suitable location, considering power supply and environmental factors.
Step-by-step guide for installing the balance, including handling transportation screws and leveling.
Procedure for connecting the AC adapter and powering on the balance, including self-check messages.
Instructions for performing span calibration, essential for accurate weighing after moving the balance.
Detailed steps for performing basic weighing operations, including taring and reading the display.
Common issues and solutions for the WindowsDirect communication function.
Explanation of why and when calibration is required for accurate weighing.
Procedures for executing span calibration and calibration checks using built-in or external weights.
Options for selecting different calibration types, including PSC and Clock-CAL.
Using the bar graph and modes for checkweighing, target setting, and judgment of pass/fail.
Guide on using the Piece Counting function, including setting the sample quantity and unit weight.
Configuration of automatic data output based on various conditions like loading or stability.
Enabling automatic zeroing when the displayed value is within the Zero Range and stability is detected.
Procedure for measuring the specific gravity of solids using the balance and a specific gravity kit.
Method for calculating liquid density by measuring a reference solid in air and the sample liquid.
| Maximum Capacity | 420 g |
|---|---|
| Readability | 0.001 g |
| Calibration | External Calibration |
| Display | LCD |
| Linearity | ±0.002 g |
| Interface | RS-232C |
| Power Supply | AC adapter |
| Repeatability (standard deviation) | 0.001 g |
| Operating Temperature Range | 5°C to 40°C |
| Power Requirements | 100-240V AC, 50/60Hz |