ADM-870C 07/14/0910
xx` n.nnnn
This display indicates that the meter is in TREND mode and that the readings are decreasing slowly. xx indicates
the units for the reading.
xx
9 n.nnnn
This display indicates that the meter is in TREND mode and that the readings are decreasing rapidly. xx indicates
the units for the reading.
xx
¸
n.nnnn
Displays the maximum (greatest value) reading stored in memory during a STORE sequence. Displayed when the
STORE key is pressed four times after HALT during the STORE sequence. Number of decimal places will vary.
xx
º n.nnnn
Displays the minimum (least value) reading stored in memory during a STORE sequence. Displayed when the
STORE key is pressed three times after HALT during the STORE sequence. Number of decimal places will vary.
xx
ºc nnnn
Displays the minimum reading of just the backpressure compensated readings stored in memory during a STORE
sequence. Displayed when the STORE key is pressed three times after HALT during the STORE sequence. If there
are no backpressure compensated readings in memory, the display will read xx
ºc NONE.
xx
¸
c nnnn
Displays the maximum reading of just the backpressure compensated readings stored in memory during a STORE
sequence. Displayed when the STORE key is pressed three times after HALT during the STORE sequence. If there
are no backpressure compensated readings in memory, the display will read xx
¸
c NONE.
xx
ºu nnnn
Displays the minimum reading of just the nonbackpressure compensated readings stored in memory during a STORE
sequence. Displayed when the STORE key is pressed three times after HALT during the STORE sequence.
xx
¸
u nnnn
Displays the maximum reading of just the nonbackpressure compensated readings stored in memory during a
STORE sequence. Displayed when the STORE key is pressed three times after HALT during the STORE sequence.
ABS PRES
This signal will be flashed when the absolute pressure mode is selected, and also each time the READ key is
pressed when in the absolute pressure mode.
ADM-870C
This message is flashed following
$ $ $ $ $ $ $ $
when the meter is first turned on.
AIRFOIL
This signal will be flashed when the AirFoil probe mode is selected and also upon each subsequent operation of the
READ key.
AUTO
This message may be one of the parameters displayed following SHIFT/SHIFT and indicates that the meter is being
used in the automatic reading mode.
AUTO READY
This message indicates that the meter has been placed in the automatic reading function. Press the READ key to
start the actual measurement. Hold the READ key down until HALT is displayed to halt the process.
AUTO STORE
This message indicates that the meter has been placed in the automatic memory mode, which integrates the
automatic reading function with the sequential storage function, and permits recall of the readings, sum or average
at any point. Press the READ key to initiate the actual reading process. Press and hold the READ key until HALT
is displayed in order to stop the automatic reading sequence.