Display | LCD |
---|---|
Data Logging | Yes |
Power Source | 4 AA batteries or AC adapter |
Temperature Range | 32 to 140 °F |
Velocity Range | 25 to 2500 FPM |
Accuracy (Air Velocity) | ±3% of reading |
Accuracy (Temperature) | ±0.5 °F (±0.3 °C) |
Connectivity | RS-232 serial interface |
Probe Type | Pitot tube |
Applications | HVAC testing |
Measurement Parameters | Air velocity, pressure, temperature, humidity |
Pressure Range | -15 to 15 in H2O |
Provides an overview of the meter's functions, capabilities, and basic operation.
Details the meter's measurement ranges and accuracy for various parameters like velocity, pressure, and temperature.
Specifies physical characteristics, memory, readout, housing, and battery life information.
Information on battery chargers and the meter's operating/storage temperature ranges.
Describes the function of each key on the meter's keypad for operation.
Details various jacks and ports for power, external control, and sensor input.
Describes the reset switch, pneumatic ports for pressure, and the serial communication port.
Explains display prompts and how measurement results are shown in English and Metric units.
Lists and explains various function prompts and messages displayed by the meter.
Provides an overview of the keypad, basic operation, and meter functions.
Explains how to manage stored readings including recall, replace, erase, and clear functions.
Instructions for downloading data to printers and computers via RS232 interface.
Details port settings, function keys, setup, and advanced WinWedge control for data transfer.
Explains the use of Kv factors for correcting velocity readings.
Describes methods for measuring velocity using Pitot tubes, AirFoil probes, and VelGrids.
Covers air flow calculation from VelGrid and comparison of local vs. standard density velocity.
Explains measuring differential pressure using probes or direct connections.
Details measuring velocity, static, and total pressures with a pitot tube.
Describes measuring absolute pressure for density correction.
Instructions for using the TemProbe for temperature readings.
Information on using the MultiTemp accessory for multiple temperature readings.
Explains the operation and use of the FlowHood for air flow measurement.
Details the backpressure compensation method for air flow measurement.
Instructions for unpacking and assembling the FlowHood kit components like frames and tops.
Details handle attachment and storage methods for the FlowHood.
How to take air flow readings without backpressure compensation.
How to take air flow readings with backpressure compensation.
Details memory display and error handling for FlowHood measurements.
Covers balancing for proportional systems, large grilles, exhaust hoods, and controllers.
Addresses diffusers, registers, short top sets, and common system problems.
Explains density corrections for barometric pressure, temperature, and relative humidity.
Compares AirData readings with hot wire anemometers and provides relevant correction formulas.
Covers meter zero function and testing differential pressure accuracy.
Details testing absolute pressure, air flow accuracy, and duct traverse comparisons.
General care and maintenance for the meter and FlowHood unit.
Information on factory calibration, repair, and product warranty.
Details NIST traceable velocity and laboratory differential pressure testing procedures.
Covers battery test procedures and tips for prolonging battery life.