6. DMX Channel Mode:
The system occupies two channels.
Motor Protect
ON/OFF
Motor protect function, default setting is
OFF
Power Selection
220/110Vac
Select input power supply voltage
Default setting for BT01 is 220VAC. BT02 is
110VAC
First Channel
Function
0-15
Fountain Off
16-39
Fountain Height 1
40-63
Fountain Height 2
64-87
Fountain Height 3
88-111
Fountain Height 4
112-135
Fountain Height 5
136-159
Fountain Height 6
160-183
Fountain Height 7
184-207
Fountain Height 8
208-231
Fountain Height 9
232-255
Fountain Height 10
Second Channel
Function
60-80
Clear Material
20-40
EMERGENCY STOP
0-10
Pre-heat OFF
240-255
Pre-heat ON