126 Operator's Manual S 65 E - S 65 E C
- Using the Enter button , select the desired mode. The selected icon is enabled
if it is in the following configuration:
- press to confirm the selection made and exit the function.
WARNING:
The list of the configuration programmes can be displayed as follows:
- Select the utility and configuration programmes icon;
- Select the configuration programmes icon;
- Select view other icons icon.
Sensitivity Calibration
Calibrate when detecting that the setting condition is out-of-tolerance or when the machine
so requires as the E 1 message is displayed.
Calibrate as follows:
1. select the sensitivity calibration icon in the configuration program menu
2. fit a wheel of average dimensions (diameter no less than 14"), with preferably only
a small unbalance, on the wheel balancer;
3. perform a spin;
4. At the end of the spin, fix the calibration weight supplied with the machine on the
swinging unit bell as indicated in figure 26.