Using the SOPAS ET configuration software, on the Illumination Control device page
During GSD parameterization with the “10_Object Trigger Ctrl” module (PROFINET
or PROFIBUS)
At the default setting, laser timeout is deactivated.
The laser diode is permanently or repeatedly switched on in the following device sta‐
tuses:
In the operating modes “Percentage evaluation” and “Auto setup”. Use these
operating modes only temporarily for configuration or diagnostics.
In reading operation in the PSDI types “Auto pulse” (adjustable duty cycle) or
“Free”
If timeout is activated, it will have no effect here.
SAFETY INFORMATION 2
8021479/19ZB/2021-10-29 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing