CommentUsed in
Binary
format
AffectsDe-
fault
value
RangeAttribute
Gives result coordinates in pixel,
millimeter or robot aligned milli-
meter format.
b
YesObject locator,
Blob, Pattern,
Single edge,
pixels{pixels, mm,
aligned}
coordUnit
Circle, Edge
counters, and
Polygon coordin-
ates
Casts to the specified datatype.
When using EtherNet/IP the at-
YesAll values{SINT, INT,
DINT, REAL}
dataType
tribute DataType specifies the
dataType section in the selected
assembly.
Used by EtherNet/IP to determ-
ine a position in the dataType
NoAll values[0, 43]pos
section in the selected as-
sembly. The first position num-
ber of the dataType section is 0.
The range of the attribute pos
depends on which assembly is
used.
YesAnglesde-
grees
{radians, de-
grees}
unit
a
Only available for Ethernet Raw.
b
The device must be calibrated for it to be possible to use the “mm” or "aligned" attribute.
Table A.4 Sizes of datatypes
EncodingRangeSizeDatatype
a
[0, 255]1 byteUSINT
a
[-128, 127]1 byteSINT
a
[0, 65535]2 bytesUINT
a
[-32768, 32767]2 bytesINT
a
[0, 2
32
-1]4 bytesUDINT
a
[-2
31
, 2
31
-1]4 bytesDINT
a
Represented as IEEE 754 binary 324 bytesREAL
a
See Section 4.2.3, “Attributes” (page 23).
51
©SICK AG • Identification & Measuring • www.sick.com • All rights reserved
Subject to change without notice
8015726/ZPP7/2018-
09
Appendix
Result output formatting
Reference Manual