Product description
30 © SICK AG · Germany · All rights reserved · Subject to change without notice 8012471/ZN27/2017-06-09
Operating Instructions
LMS1xx Laser Measurement Sensors
Chapter 3
LMS14x:
Fig. 17: LMS14x: Beam diameter and distance between measured points at 0 m to 40 m
Example for angular resolution 0,50° in Fig. 17
Distance 40 m
Distance intersection point 40 m gives a distance between the measured points of approx.
350
mm
Distance intersection point 40 m with the characteristic curve for beam diameter gives a
beam size of approx. 608
mm
LMS15x:
Fig. 18: LMS15x: Beam diameter and distance between measured points at 0 to 50 m
Beam
diameter
0
Distance [m]
Size [mm]
20
0
100
1000
200
0.25° Angle
resolution
Beam diameter
10
300
Distance between measured points
0.5° Angle
resolution
400
500
600
700
800
900
30 40
Beam
diameter
0
Distance [m]
Size [mm]
20
0
100
1000
200
0.25° Angle
resolution
Beam diameter
10
300
Distance between measured points
0.5° Angle
resolution
400
500
600
700
800
900
30 40 50