Table 2: Safety-related PROFIsafe process image: output of the device, input of the control
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 Reserved Manipula‐
t
ionStatus
Reference‐
ContourSta‐
tus
Contamina‐
tionError
Contamina‐
tionWarning
Standbymo‐
deActive
RunModeac‐
tive
1
1)
SafeCutOff‐
Path08
SafeCutOff‐
Path07
SafeCutOff‐
Path06
SafeCutOff‐
Path05
SafeCutOff‐
Path04
SafeCutOff‐
Path03
SafeCutOff‐
Path02
SafeCutOff‐
Path01
2 Reserved
3
1)
NonsafeCu‐
tOf
fPath08
NonsafeCu‐
tOffPath07
NonsafeCu‐
tOffPath06
NonsafeCu‐
tOffPath05
NonsafeCu‐
tOffPath04
NonsafeCu‐
tOffPath03
NonsafeCu‐
tOffPath02
NonsafeCu‐
tOffPath01
4 Reserved
5
1)
ResetRequir‐
edCutOff‐
Path08
ResetRequir‐
edCutOff‐
Path07
ResetRequir‐
edCutOff‐
Path06
ResetRequir‐
edCutOff‐
Path05
ResetRequir‐
edCutOff‐
Path04
ResetRequir‐
edCutOff‐
Path03
ResetRequir‐
edCutOff‐
Path02
ResetRequir‐
edCutOff‐
Path01
6 Reserved
7 CurrentMonitoringCaseNoTable1
8 Reserved
9 Reserved
10 Reserved
11 Reserved DeviceError Applicatio‐
nEr
ror
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
Table 3: Non-safety-related PROFINET process image: output of the device, input of the control
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 Reserved Manipula‐
t
ionStatus
Reference‐
ContourSta‐
tus
Contamina‐
tionError
Contamina‐
tionWarning
Standbymo‐
deActive
RunModeac‐
tive
1
1)
StatusSafe‐
CutOf
f‐
Path08
StatusSafe‐
CutOff‐
Path07
StatusSafe‐
CutOff‐
Path06
StatusSafe‐
CutOff‐
Path05
StatusSafe‐
CutOff‐
Path04
StatusSafe‐
CutOff‐
Path03
StatusSafe‐
CutOff‐
Path02
StatusSafe‐
CutOff‐
Path01
2 Reserved
3
1)
NonsafeCu‐
tOffPath08
NonsafeCu‐
tOffPath07
NonsafeCu‐
tOffPath06
NonsafeCu‐
tOffPath05
NonsafeCu‐
tOffPath04
NonsafeCu‐
tOffPath03
NonsafeCu‐
tOffPath02
NonsafeCu‐
tOffPath01
4 Reserved
5
1)
ResetRequir‐
edCutOf
f‐
Path08
ResetRequir‐
edCutOff‐
Path07
ResetRequir‐
edCutOff‐
Path06
ResetRequir‐
edCutOff‐
Path05
ResetRequir‐
edCutOff‐
Path04
ResetRequir‐
edCutOff‐
Path03
ResetRequir‐
edCutOff‐
Path02
ResetRequir‐
edCutOff‐
Path01
6 Reserved
7 CurrentMonitoringCaseNoTable1
8 Reserved
9 Reserved
10 Reserved
11 Reserved DeviceError Applicatio‐
nEr
ror
1)
Cut-off paths 5 to 8 are only available for the Pro performance package.
OVERVIEW OF THE PROCESS IMAGES 4