EasyManua.ls Logo

SICK MultiTask RAY10 Series - Troubleshooting; Time function setting; Light;dark switch

SICK MultiTask RAY10 Series
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
2
1
2
1
3
1-2 mm
3 Time function setting
0 s 2 s
Figure 9: Time function switch
RAY10-xxxxxM: ON delay, time delay when object is detected.
RAY10-xxxxxN: OFF delay, time delay when object is detected not any longer.
The time (0 ... 2 sec.) can be selected by turning the potentiometer up against left (0 sec.)
or turning up against right (2 sec.).
4 Light/dark switch
DO LO
Figure 10: Light / dark switch
RAY10-xxxxxP: The sensor is in light switching mode when optional light/dark potentiome‐
ter is rotated to the “LO” position. The sensor is in dark switching mode when optional
light/dark potentiometer is rotated to the “DO” position. The green power supply LED will
flash once when the mode is changed. see table 5.
8 Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 9: Troubleshooting
LED indicator/fault pattern Cause Measures
Yellow LED does not light up
even though the light beam is
aligned to the reflector and
there is no object in the path of
the beam
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Voltage interruptions Ensure there is a stable power
supply without interruptions
TROUBLESHOOTING 8
8022198 | SICK
Subject to change without notice
13