6.3 Connecting cable with flying leads, 17-wire
Voltage supply and local inputs and outputs
Flying leads
17-wire
Pin assignment of the connecting cable with flying leads, 17-wire
Wire color Designation Function
Brown 24 V DC Supply voltage (+24 V DC)
Blue 0 V DC Supply voltage (0 V DC)
White OSSD 1.A OSSD pair 1, OSSD A
Green OSSD 1.B OSSD pair 1, OSSD B
Pink Uni-I/O 1 Universal I/O 1, configurable:
S
tatic control input B1
Universal input: sleep mode, restarting the device
Universal output: contamination, fault, reset required
(OSSD pair 1), monitoring result
Yellow Uni-I/O 2 Universal I/O 2, configurable:
OSSD pair 2, OSSD A (OSSD 2.A)
Static control input A1
Universal input: sleep mode, restarting the device
Universal output: contamination, error, monitoring
result
Black Uni-I/O 3 Universal I/O 3, configurable:
O
SSD pair 2, OSSD B (OSSD 2.B)
Static control input A2
Universal input: sleep mode, restarting the device
Universal output: contamination, error, monitoring
result
Gray Uni-I/O 4 Universal I/O 4, configurable:
Static control input B2
Universal input: sleep mode, restarting the device
Universal output: contamination, fault, reset required
(OSSD pair 2), monitoring result
Red Uni-in 1 Universal input 1, configurable:
Static control input C1
Dynamic control input 1a (0°)
Universal input: sleep mode, restarting the device
Violet Uni-in 2 Universal input 2, configurable:
Static control input C2
Dynamic control input 1b (90°)
Universal input: sleep mode, restarting the device
Grey/Pink Uni-in 3 Universal input 3, configurable:
S
tatic control input D1
Dynamic control input 2a (0°)
Universal input: sleep mode, restarting the device
Red/Blue Uni-in 4 Universal input 4, configurable:
Static control input D2
Dynamic control input 2b (90°)
Universal input: sleep mode, restarting the device